2009 IEEE Electrical Insulation Conference 2009
DOI: 10.1109/eic.2009.5166335
|View full text |Cite
|
Sign up to set email alerts
|

Advantage of On-Line Partial Discharge continuous monitoring of medium voltage substation

Abstract: On-Line Continuous Partial Discharge measurements of medium voltage substations have not attracted the same attention in the electrical community as compared to similar PD measurements of rotating machines. The cost of an unexpected outage however may be considerably more significant of a main distribution bus than just for a single motor failure. This paper discusses pros and cons of PD measurements using multiple sensors for additional noise reduction and localizing PD activity for measurements made in highe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0
2

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 5 publications
0
2
0
2
Order By: Relevance
“…Deteksi online tidak perlu dimatikan dan dapat menggunakan banyak sensor untuk mengukur PD. Oleh karena itu, deteksi online merupakan pengukuran yang direkomendasikan dalam beberapa tahun terakhir [5][6][7]. Partial Discharge yang terjadi terus menerus dapat menyebabkan kerusakan (breakdown) pada suatu peralatan tegangan tinggi.…”
Section: Pendahuluanunclassified
“…Deteksi online tidak perlu dimatikan dan dapat menggunakan banyak sensor untuk mengukur PD. Oleh karena itu, deteksi online merupakan pengukuran yang direkomendasikan dalam beberapa tahun terakhir [5][6][7]. Partial Discharge yang terjadi terus menerus dapat menyebabkan kerusakan (breakdown) pada suatu peralatan tegangan tinggi.…”
Section: Pendahuluanunclassified
“…On-line continuous PDs measurements of medium voltage substations are the similar as PDs measurements of rotating machines. We can used multiple sensors for additional noise reduction and localizing PD activity for measurements made in higher frequency bands [14]. An experimental investigation of the behaviour of PDs occurring in insulation cavities under influence of different voltage, temperature and electrical field conditions is presented in this paper.…”
Section: On-line Monitoring Of Partial Dischargesmentioning
confidence: 99%
“…Bu sayede uzun süreli kesintilerin ve enerji kalitesindeki bozulmaların önüne geçebilmek mümkündür. [16]'da orta gerilim dağıtım merkezlerinde kısmi deşarj ölçümlerinin avantajları ve dezavantajları tartışılmaktadır. [17]'de orta gerilim metal clad hücrelerde yalıtım durumunun değerlendirilmesini için farklı elektromanyetik kısmi deşarj ölçüm tekniklerinin uygulanmasına ilişkin bir çalışma sunulmaktadır.…”
Section: Gi̇ri̇ş (Introduction)unclassified