2001
DOI: 10.1016/s1350-4487(01)00177-9
|View full text |Cite
|
Sign up to set email alerts
|

Advantage of PM-355 nuclear track detector in light-ion registration and high-temperature plasma diagnostics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 7 publications
0
12
0
Order By: Relevance
“…34͒ and d L was relatively large ͑10-50 m͒, the conditions for ion acceleration were not very different from those required for SLPA, especially for larger d L . The proton beam characteristics were measured using the time-of-flight method ͑ion charge collectors 38 40 with Al filters͒ and RCF stacks measured with a sufficient resolution only high-energy protons ͑Ն3 MeV͒, as these detectors were strongly saturated by moderate-energy protons at the target-detector distances employed ͑L SSTD = 123 cm, L RCF = 2.5 cm͒. The effect of the laser intensity and the target structure ͑single layer, double layer͒ on the proton beam parameters was studied.…”
Section: Results Of Experiments and Discussionmentioning
confidence: 99%
“…34͒ and d L was relatively large ͑10-50 m͒, the conditions for ion acceleration were not very different from those required for SLPA, especially for larger d L . The proton beam characteristics were measured using the time-of-flight method ͑ion charge collectors 38 40 with Al filters͒ and RCF stacks measured with a sufficient resolution only high-energy protons ͑Ն3 MeV͒, as these detectors were strongly saturated by moderate-energy protons at the target-detector distances employed ͑L SSTD = 123 cm, L RCF = 2.5 cm͒. The effect of the laser intensity and the target structure ͑single layer, double layer͒ on the proton beam parameters was studied.…”
Section: Results Of Experiments and Discussionmentioning
confidence: 99%
“…The important ion characteristics have been measured, e.g., angular distributions, energy spectra and ion sources locations (Sadowski et al, 1999;Szydlowski, 2003). In order to use such detectors in an optimal way extensive calibration measurements of the selected detectors have been performed in our laboratory (Szydlowski et al, 2001(Szydlowski et al, , 2002. Recently, we made an attempt to record and analyze fast ions emitted from the other high-temperature plasma experiments.…”
Section: Introductionmentioning
confidence: 99%
“…In this paper, some rectangular samples (cut into about 1 × 3 cm 2 pieces) with a thickness of 0.5 mm of the PM-355 type detector were irradiated with light ions (H + -and D + -ions) of different energies provided by various particle accelerators, but mainly by the LECH accelerator (Van de Graaff type) [16][17][18][19][20][21]. These samples were prepared from the detector batch bought from the Page Pershore Moulding Company in 2009 [15].…”
Section: Methodsmentioning
confidence: 99%
“…These results were obtained using commercial PM-355 material and we partly published them in our previous publications [15][16][17][18][19][20]. In this paper, we report on a track analysis performed by a semiautomatic system that selected tracks according to two parameters, diameter of the etched pits and mean gray level.…”
Section: Introductionmentioning
confidence: 99%