2004
DOI: 10.1007/s00134-004-2267-8
|View full text |Cite
|
Sign up to set email alerts
|

Advantages and disadvantages of different nasal CPAP systems in newborns

Abstract: The naso-pharyngeal tube is an easy, safe and economical CPAP system usable with every common ventilator. For very low birth weight newborns, a prong system may have advantages.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
41
0
4

Year Published

2008
2008
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 83 publications
(46 citation statements)
references
References 11 publications
1
41
0
4
Order By: Relevance
“…The mild stage is described as redness or nasal hyperemia; the moderate presents bleeding injuries and the severe stage refers to injuries with necrosis (5) .…”
Section: Continuous Positive Airway Pressure (Cpap) It Is a Mechanicmentioning
confidence: 99%
See 1 more Smart Citation
“…The mild stage is described as redness or nasal hyperemia; the moderate presents bleeding injuries and the severe stage refers to injuries with necrosis (5) .…”
Section: Continuous Positive Airway Pressure (Cpap) It Is a Mechanicmentioning
confidence: 99%
“…Nasal lesions caused in newborns due to misuse of prongs vary from simple hyperemia of the nasal mucosa, bleeding, formation of crusts, and necrosis up to total destruction of the anterior part of the septum (columella) (6)(7) and nasal septum (5,8) .…”
Section: Continuous Positive Airway Pressure (Cpap) It Is a Mechanicmentioning
confidence: 99%
“…[5,6] The local pressure of nasal prongs to the nasal region is easy to cause nasal injury in the newborn due to the cutaneous vulnerability. [6,7] Besides anatomical factors, such as endvascularization of the columella and nostrils, [8] Diblasi [9] emphasized that fixation technique was also an important factor for selecting the proper hat and prongs. The lack of stabilization and, hence, excessive movement of the prongs could result in nasal injury, interface displacement, and loss of system pressure.…”
Section: Introductionmentioning
confidence: 99%
“…25 As for the type of the flow generator, studies have shown no significant difference in outcomes using the different types of flow generators to deliver NCPAP. 26 Extubation failures requiring reintubation ranged from 20 to 80% in infants managed on NCPAP with higher failure rates in extremely low birth weight infants. Most common reasons for failures of the use of NCPAP included repeated episodes of apnea, desaturation, bradycardia or respiratory acidosis.…”
Section: Nasal Cpapmentioning
confidence: 98%