Agent‐based identification and control of voltage emergency situations

Abstract: Changing dynamics of power systems caused by the migration from conventional to distributed energy sources increase the risk of blackouts due to voltage instability, especially in case of unforeseen network conditions (e.g., (N-k)-cases). To enable a both secure and efficient power supply, novel monitoring and emergency control systems for the identification of voltage emergency situations as well as the execution of control actions are required that react reliably in due time and adaptively in case of changin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 28 publications
0
1
0
1
Order By: Relevance
“…Since it maps higher voltage levels, integration of DERs is considered in terms of adjusted distribution system loads. As shown by several current publications, the Nordic 32 test system is still very relevant for power system analysis today [56,57,58,59]. Further, it is supported by the fact that the Nordic cycles [61] compared to the ICT sector.…”
Section: Smart Grid Reference Scenario and Mapping On A Corresponding...mentioning
confidence: 99%
“…Since it maps higher voltage levels, integration of DERs is considered in terms of adjusted distribution system loads. As shown by several current publications, the Nordic 32 test system is still very relevant for power system analysis today [56,57,58,59]. Further, it is supported by the fact that the Nordic cycles [61] compared to the ICT sector.…”
Section: Smart Grid Reference Scenario and Mapping On A Corresponding...mentioning
confidence: 99%
“…Συνέχεια των παραπάνω εργασιών αποτελούν οι[VLG10] και[VLK15], στις οποίες παρουσιάζεται ολοκληρωμένο και αποκεντρωμένο σύστημα προστασίας από κατάρρευση τάσης, ενσωματώνοντας σύστημα άμεσης αποκοπής φορτίου για την προστασία συστήματος από κατάρρευση. Στην εργασία[RWH13] παρουσιάζεται ένα διανεμημένο σύστημα ανίχνευσης αστάθειας τάσης και προστασίας συστήματος βασισμένο σε παραλλαγή της μεθόδου της εργασίας[VVC08]. Η αρχική παραλλαγή παρουσιάζεται στο[WPV17], η οποία εκτιμά την αδυναμία ρύθμισης του ΣΑΤΥΦ από τη μακροπρόθεσμη συμπεριφορά της ελεγχόμενης από το ΣΑΤΥΦ τάσης, χρησιμοποιώντας παλινδρόμηση με αναδρομικά γραμμικά ελάχιστα τετράγωνα.…”
unclassified