2010
DOI: 10.1016/j.apergo.2009.07.009
|View full text |Cite
|
Sign up to set email alerts
|

Air management and physiological responses during simulated firefighting tasks in a high-rise structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

9
63
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(73 citation statements)
references
References 12 publications
9
63
0
1
Order By: Relevance
“…Fire fighting and rescue work may be very demanding for the cardiorespiratory system [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28]. However, all these studies have some limitations in examining physical demands of real fire fighting.…”
Section: E Von Heimburg and Ji Medbø Jose 2013 Vol 19 Nomentioning
confidence: 99%
See 2 more Smart Citations
“…Fire fighting and rescue work may be very demanding for the cardiorespiratory system [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28]. However, all these studies have some limitations in examining physical demands of real fire fighting.…”
Section: E Von Heimburg and Ji Medbø Jose 2013 Vol 19 Nomentioning
confidence: 99%
“…Thus, the lower air consumption needed to perform a specific set of tasks is another advantage of being physically fit. Former studies described problems and limitations of air reserve during smoke diving [14,19,22,23,24]. Several studies showed that a firefighter may run out of air within ~20 min during strenuous exercise.…”
Section: Test Duration Air Consumption and Pulmonary Ventilationmentioning
confidence: 99%
See 1 more Smart Citation
“…This was highlighted with actual measurement of air demand from the SCBA for incumbent firefighters during a simulated high-rise ascent to perform search and rescue (Williams-Bell et al 2010a) as well as a search and rescue scenario in a smoke-filled subway (Williams-Bell et al 2010b). In both of these studies air demand was positively correlated to body mass.…”
Section: Protective Clothing Equipment Load Carriage and Aerobic Fimentioning
confidence: 99%
“…In both of these studies air demand was positively correlated to body mass. Only 6 of 36 firefighters (33 men and 3 women) were able to ascend 23 floors without activating their low-air alarm on the SCBA (Williams-Bell et al 2010a) and one of these was a 60-kg female (F.M. Williams-Bell, personal communication).…”
Section: Protective Clothing Equipment Load Carriage and Aerobic Fimentioning
confidence: 99%