Airborne Chlordane Contamination in Houses Treated for Termites at a Midwestern Air Force Base

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1981
1981
2011
2011

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…In slab construction houses in which the heating and ventilation ducts are below the ground floor, C/H residues can be carried into the air and onto surfaces of the living areas [36]. In a survey of 435 U.S. Air Force homes treated from 1964 to 1978 and monitored in 1979, 60% had chlordane levels over 1 ,ug/m3; the mean concentration in 77% of homes with detectable levels was 2 pg/m3 [37]. Similarly, a recent survey of 1,110 air samples from 422 homes in 14 counties of New York state showed that levels of chlordane in excess of 5 &m3 were found in 33% of 289 nonliving area samples and 7% of 661 living area samples [38].…”
Section: Domestic Exposure To Chlordaneiheptachlormentioning
confidence: 99%
“…In slab construction houses in which the heating and ventilation ducts are below the ground floor, C/H residues can be carried into the air and onto surfaces of the living areas [36]. In a survey of 435 U.S. Air Force homes treated from 1964 to 1978 and monitored in 1979, 60% had chlordane levels over 1 ,ug/m3; the mean concentration in 77% of homes with detectable levels was 2 pg/m3 [37]. Similarly, a recent survey of 1,110 air samples from 422 homes in 14 counties of New York state showed that levels of chlordane in excess of 5 &m3 were found in 33% of 289 nonliving area samples and 7% of 661 living area samples [38].…”
Section: Domestic Exposure To Chlordaneiheptachlormentioning
confidence: 99%
“…This incident resulted in the residents of the unit becoming physically ill immediately following application of the chlordane but with no apparent lasting signs of exposure. Two reports published in 1981 surveyed housing units with ventilation ducts either in or under the slab and that underwent post-construction treatment for termites by sub-slab injection of a chlordane emulsion (Livingston et al 1981, Lillie 1981. The results of these surveys indicated that a large majority of these units, 969, exhibited measurable indoor air concentrations of chlordane.…”
Section: Historical Usage and Reported Problemsmentioning
confidence: 99%
“…Other studies were conducted at Wright-Patterson AFB in newly constructed houses that were pretreated with chlordane (unpublished data 1976). Livingston et al (1981) reported the contamination of houses at Scott AFB following the application of chlordane by subslab injection.…”
Section: H €Lssipied Security Classification Of This Page (When Dawmentioning
confidence: 99%