2013 International Conference on Information Communication and Embedded Systems (ICICES) 2013
DOI: 10.1109/icices.2013.6508187
|View full text |Cite
|
Sign up to set email alerts
|

Airfield Lamp Monitoring & Control Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…Nevertheless, little research effort has been devoted to the improvement of this location procedure. Computer controlled monitoring of the AGL system for locating failed luminaires is proposed in [3] − [6]. A PLC system could be used between the luminaires and CCRs to avoid interaction of wireless technologies with radio navigation instruments and installation of new cables in AGL circuits [3], [5], [6].…”
Section: B Comparison With Other Procedures For Failed Luminaire Locmentioning
confidence: 99%
See 2 more Smart Citations
“…Nevertheless, little research effort has been devoted to the improvement of this location procedure. Computer controlled monitoring of the AGL system for locating failed luminaires is proposed in [3] − [6]. A PLC system could be used between the luminaires and CCRs to avoid interaction of wireless technologies with radio navigation instruments and installation of new cables in AGL circuits [3], [5], [6].…”
Section: B Comparison With Other Procedures For Failed Luminaire Locmentioning
confidence: 99%
“…Computer controlled monitoring of the AGL system for locating failed luminaires is proposed in [3] − [6]. A PLC system could be used between the luminaires and CCRs to avoid interaction of wireless technologies with radio navigation instruments and installation of new cables in AGL circuits [3], [5], [6]. PLC modems are installed in the secondary circuits of AGL transformers to detect luminaire failures and a central PLC modem is installed in the CCR room to receive and process information of failed luminaires.…”
Section: B Comparison With Other Procedures For Failed Luminaire Locmentioning
confidence: 99%
See 1 more Smart Citation
“…These systems are single-phase series circuits where constant current regulators (CCRs) supply luminaires through transformers with voltages up to 5 kV (see Fig. 1) [1][2][3][4][5][6][7][8][9]. CCRs are variable voltage sources, [10,11], which provide an adjustable root mean square (rms) current according to luminaire brightness requirements and ensure circuit continuity, even in case of luminaire failure [4,6,7].…”
Section: Introductionmentioning
confidence: 99%
“…cable insulation failure and lightning strikes) [7,14,16], system control (e.g. lamp monitoring) [3,4,5,12] and future technological changes (e.g. changes in luminaire technology) [13].…”
Section: Introductionmentioning
confidence: 99%