47th AIAA Aerospace Sciences Meeting Including the New Horizons Forum and Aerospace Exposition 2009
DOI: 10.2514/6.2009-531
|View full text |Cite
|
Sign up to set email alerts
|

Airfoil Flow Experiment on the Duty Cycle of DBD Plasma Actuator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
44
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 51 publications
(46 citation statements)
references
References 4 publications
1
44
1
Order By: Relevance
“…Figure 6 shows the mean pressure coefficients for the simulation and experimental results. The detailed experimental setup and measuring method are given in previous papers [58,59]. It is noted that, since the plasma actuator is located at x∕c 0.05, the pressure data at this location cannot be measured in this experiment.…”
Section: F Flow Condition and Computational Casementioning
confidence: 98%
See 1 more Smart Citation
“…Figure 6 shows the mean pressure coefficients for the simulation and experimental results. The detailed experimental setup and measuring method are given in previous papers [58,59]. It is noted that, since the plasma actuator is located at x∕c 0.05, the pressure data at this location cannot be measured in this experiment.…”
Section: F Flow Condition and Computational Casementioning
confidence: 98%
“…The flow condition is supposed to be the same as our previous experiment at a low Reynolds number [58]. In this experiment, the freestream velocity was 10 m∕s, and the chord length of the NACA 0015 airfoil was 10 cm, resulting in a Reynolds number of 63,000.…”
Section: F Flow Condition and Computational Casementioning
confidence: 99%
“…Many researchers investigate the optimum F + value for separation control over an airfoil, and there are two assertions: 1) F + ≈ O(1) is the optimum frequency 11, 12, 14 and 2) F + ≈ O(10) is the optimum frequency. 13,15 This inconsistency may be due to lack of understanding of the separation control mechanism.…”
Section: Introductionmentioning
confidence: 94%
“…Flow conditions is set same as the previous experimental study 15 to conduct the validation. Free stream Mach number is M ∞ = 0.2.…”
Section: Computational Flow Conditionsmentioning
confidence: 99%
“…In these studies, continuous DC current was applied with different parameters such as DC voltage, frequencies and shape of the frequency waves. Some studies demonstrated that the so-called 'burst mode' (schematically shown in figure 2) with duty cycles has better capability to control flow separation with less energy consumption [4,6,7,10,14,16,18]. Here, the burst mode actuation indicates that the base high-frequency wave signals are periodically switched on and off with a low burst frequency.…”
Section: Introductionmentioning
confidence: 99%