2011
DOI: 10.1097/ta.0b013e3181e75873
|View full text |Cite
|
Sign up to set email alerts
|

Airway Scope Laryngoscopy Under Manual Inline Stabilization and Cervical Collar Immobilization: A Crossover In Vivo Cinefluoroscopic Study

Abstract: When compared with cervical collar immobilization, AWS laryngoscopy along with MIS seems to be a safer and more definite method to secure airway of neck-injured trauma patients because it limits less mouth opening and upper cervical spine movement.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(16 citation statements)
references
References 15 publications
0
16
0
Order By: Relevance
“…Then again, the Pentax-AWS may also have some limitations for intubation because failed tracheal intubations using the Pentax-AWS have been reported in patients with a long distance from the mouth to the larynx and with a smaller mouth opening. 4,5 We also failed to intubate this patient's trachea using the Pentax-AWS, probably because of the relatively short interincisor distance (30 mm) and the long thyromental distance (85 mm). …”
Section: To the Editormentioning
confidence: 99%
“…Then again, the Pentax-AWS may also have some limitations for intubation because failed tracheal intubations using the Pentax-AWS have been reported in patients with a long distance from the mouth to the larynx and with a smaller mouth opening. 4,5 We also failed to intubate this patient's trachea using the Pentax-AWS, probably because of the relatively short interincisor distance (30 mm) and the long thyromental distance (85 mm). …”
Section: To the Editormentioning
confidence: 99%
“…[2] There was a wide and unpredictable variation between subjects in the reduction in mouth opening and a significant proportion were reported to have inter-incisor distance of 20 mm or less in the presence of rigid cervical collar. [81214] In a report by Aoi et al ., 7 of 9 failed cases in the study had Inter Incisor distance < 10 mm which was insufficient to insert the 18 mm blade of airway scope. [12] In the present study, insertion of Airtraq ® was possible in all patients despite restriction of mouth opening.…”
Section: Discussionmentioning
confidence: 99%
“…[81214] In a report by Aoi et al ., 7 of 9 failed cases in the study had Inter Incisor distance < 10 mm which was insufficient to insert the 18 mm blade of airway scope. [12] In the present study, insertion of Airtraq ® was possible in all patients despite restriction of mouth opening. The recommended mouth opening for no.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations