2002
DOI: 10.1053/ajkd.2002.33388
|View full text |Cite
|
Sign up to set email alerts
|

Albumin to creatinine catio: A screening test with limitations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
59
0
1

Year Published

2003
2003
2017
2017

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 94 publications
(63 citation statements)
references
References 17 publications
3
59
0
1
Order By: Relevance
“…16 In a study by Houlihan et al the sensitivity was found to be 95.7% in males and 93.35% in females. 17 The sensitivity at different cut off levels of ACR in the present study was found to vary from 97% at cut off of 1mg/mmol to 55% at 8mg/mmol in males and in females it was found to be 92% at cut off of 1 mg/mmol and 78% at cut off of 8mg/mmol. The specificity was 63% at 1 mg/mmol and 98% at 8mg/mmol in males and 50% at 1mg/mmol and 99% at 8mg/mmol in females indicating its role in diagnosing normoalbuminuric patients at lower range and patients with high microalbuminuria at higher range.…”
Section: Resultssupporting
confidence: 41%
“…16 In a study by Houlihan et al the sensitivity was found to be 95.7% in males and 93.35% in females. 17 The sensitivity at different cut off levels of ACR in the present study was found to vary from 97% at cut off of 1mg/mmol to 55% at 8mg/mmol in males and in females it was found to be 92% at cut off of 1 mg/mmol and 78% at cut off of 8mg/mmol. The specificity was 63% at 1 mg/mmol and 98% at 8mg/mmol in males and 50% at 1mg/mmol and 99% at 8mg/mmol in females indicating its role in diagnosing normoalbuminuric patients at lower range and patients with high microalbuminuria at higher range.…”
Section: Resultssupporting
confidence: 41%
“…A 24-h urine collection for the diagnosis of albuminuria remains the gold standard; however, because of the inconvenience and errors associated with a timed urine sample, a spot urine sample using either albumin-specific dipstick or albumin-to-creatinine ratio is now an accepted screening method (22,29). Houlihan et al (30) assessed the characteristics of the albumin-to-creatinine ratio as a screening test and found sensitivities Ͼ90% for both men and women, with excellent accuracy reflected by area under the receiver operator characteristics curve. Recently, both the Prevention of Renal and Vascular Endstage Disease (PREVEND) study group in Europe (29) and Jafar et al (31) in an Indo-Asian population assessed the validity of urinary albumin concentration and the albumin-to-creatinine ratio to detect individuals with microalbuminuria in subsequent 24-h urine samples.…”
Section: Definition and Tests For Ckd Screeningmentioning
confidence: 99%
“…The ACR ratio was expressed in mg/g. Cutoff values for microalbuminuria were gender-and ageadjusted according to Houlihan et al 18 Macroalbuminuria was defined as ACRX300 mg/g. Three cases were positive for urinary nitrites and they were excluded from the analysis.…”
Section: Biochemical Measurementsmentioning
confidence: 99%