Algorithmic tools for optimizing the temperature regime of evaporator at absorption-refrigeration units of ammonia production

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…Under such conditions, the solution degassing zone will increase and the efficiency of the heat exchange process in the generator will increase. At the same time, the pressure value at the point of entry of the solid solution to the generator and the pressure difference in the generator cube and at the outlet of the rectifier, which is due to hydrodynamics, were calculated according to the equation given in [12]. Removal of steam from the dephlegmator scheme with a strong solution will result in a decrease in the temperature of the weak solution at the absorber inlet to a value of no more than 43 °С (67 °С according to the project) and a decrease in the heat load on the absorber.…”
Section: The Study Materials and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Under such conditions, the solution degassing zone will increase and the efficiency of the heat exchange process in the generator will increase. At the same time, the pressure value at the point of entry of the solid solution to the generator and the pressure difference in the generator cube and at the outlet of the rectifier, which is due to hydrodynamics, were calculated according to the equation given in [12]. Removal of steam from the dephlegmator scheme with a strong solution will result in a decrease in the temperature of the weak solution at the absorber inlet to a value of no more than 43 °С (67 °С according to the project) and a decrease in the heat load on the absorber.…”
Section: The Study Materials and Methodsmentioning
confidence: 99%
“…The occurrence of such a situation is clearly illustrated by such a concept as the multiplicity of circulation of solutions f, which largely characterizes the work of ARU [7]. The value f is determined by the ratio of the difference in ammonia concentrations in the water-ammonia vapor from the dephlegmator (rectifier) ξ df and weak solution ξ a to the degassing zone, which is the difference in ammonia concentrations in strong ξ r and weak ξ a water-ammonia solutions.…”
Section: Literature Review and Problem Statementmentioning
confidence: 99%
See 1 more Smart Citation