2015
DOI: 10.1120/jacmp.v16i6.5733
|View full text |Cite
|
Sign up to set email alerts
|

Alignment of multiradiation isocenters for megavoltage photon beam

Abstract: The accurate measurement of the linear accelerator (linac) radiation isocenter is critical, especially for stereotactic treatment. Traditional quality assurance (QA) procedure focuses on the measurement of single radiation isocenter, usually of 6 megavoltage (MV) photon beams. Single radiation isocenter is also commonly assumed in treatment planning systems (TPS). Due to different flattening filters and bending magnet and steering parameters, the radiation isocenter of one energy mode can deviate from another … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 13 publications
0
6
0
2
Order By: Relevance
“…To address this issue, many researchers have attempted to integrate multiple isocenter measurements into one system or procedure. [20][21][22][23] Note that Fuse et al developed a new device which can compute the offset value of the radiation isocenter from the imaging isocenter by using the radiosensitive film. 24 And modified Winston Lutz test could compare radiation isocenter to mechanical isocenter, 25 to imaging isocenter.…”
Section: Discussionmentioning
confidence: 99%
“…To address this issue, many researchers have attempted to integrate multiple isocenter measurements into one system or procedure. [20][21][22][23] Note that Fuse et al developed a new device which can compute the offset value of the radiation isocenter from the imaging isocenter by using the radiosensitive film. 24 And modified Winston Lutz test could compare radiation isocenter to mechanical isocenter, 25 to imaging isocenter.…”
Section: Discussionmentioning
confidence: 99%
“…In clinical quality assurance procedure, static open‐field EPID images of a ball‐bearing phantom at several gantry angles were evaluated to detect the isocenter shift 12 . However, the real VMAT delivery is more complicated because the gantry rotation speed changes dynamically 5,13,14 . We measured the open‐field EPID images in both clockwise and counterclockwise directions at several rotation speeds by changing the dose rates (100, 400, and 700 MU/min), and generated a set of flex maps.…”
Section: Methodsmentioning
confidence: 99%
“…12 However, the real VMAT delivery is more complicated because the gantry rotation speed changes dynamically. 5,13,14 We measured the open-field EPID images in both clockwise and counterclockwise directions at several rotation speeds by changing the dose rates (100, 400, and 700 MU/min), and generated a set of flex maps. Based on the rotation directions and speed, the flex map for a specific VMAT arc delivery could be interpolated from the set of flex maps we generated,and the acquired EPID image were corrected using the specific flex map.…”
Section: Mlc Motion Modelingmentioning
confidence: 99%
“…Sendo: A medida da acurácia do isocentro no acelerador linear é crítica, e necessária para o controle de qualidade na radioterapia. No estudo 11 publicado em 2015 foi desenvolvido um teste com diferentes faixas de energia, observou um desvio máximo de 1.39 mm, para a faixa de energia de 10 MV.…”
Section: Digitalização Do Portal Film E Método Deunclassified