2012 IEEE 15th International Conference on Harmonics and Quality of Power 2012
DOI: 10.1109/ichqp.2012.6381249
|View full text |Cite
|
Sign up to set email alerts
|

Allocation of power harmonic filters using Genetic Algorithm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 5 publications
0
3
0
2
Order By: Relevance
“…The processes and values utilized in this paper are predicated on a prior sensitivity analysis of the method mentioned in references [24,25]. If an inequality constraint is violated, a penalty factor is applied to the fitness function [26].…”
Section: Application Of Genetic Algorithm (Ga) To the Suggested Optim...mentioning
confidence: 99%
“…The processes and values utilized in this paper are predicated on a prior sensitivity analysis of the method mentioned in references [24,25]. If an inequality constraint is violated, a penalty factor is applied to the fitness function [26].…”
Section: Application Of Genetic Algorithm (Ga) To the Suggested Optim...mentioning
confidence: 99%
“…Using FTU IOP Publishing doi:10.1088/1742-6596/2774/1/012016 2 telecommunication signals, we can effectively achieve fault location. In addition to the algorithms mentioned above, there are other intelligent optimization algorithms [8] that are widely used in fault location in distribution networks, such as artificial immunity algorithms [9], bee colony algorithms [10], harmonic algorithms [11], bat algorithms [12], grey wolf optimization algorithms [13] and so on.…”
Section: Introductionmentioning
confidence: 99%
“…As alterações destas formas de ondas senoidais de tensão e de corrente são definidos como distorções harmônicas. O uso crescente de cargas não lineares conectadas a toda e qualquer rede elétrica, como os equipamentos eletrônicos, faz com que as distorções harmônicas cresçam a cada dia fazendo com que o desafio de identificar e corrigir níveis excessivos de harmônicos seja cada vez maior (Arrillaga e Watson, 2004), (Variz et al, 2008), (Variz et al, 2012), (IEEE, 2014).…”
Section: Introductionunclassified
“…Apesar dos seus múltiplos benefícios, como o aumento da matriz energética do país, essas fontes são associadasà uma notável intermitência eà diversos problemas de qualidade de energia, incluindo o aparecimento de distorções harmônicas (Peterson et al, 2017). Consequentemente, há uma necessidade de prover meios para a modelagem e representação dos componentes do sistema de potência no domínio da frequência (Variz et al, 2008), (Variz et al, 2012), (Levačić et al, 2019), (Melo et al, 2020), (de Melo et al, 2019), (Sharma et al, 2018).…”
Section: Introductionunclassified