Symposium on the Application of Geophysics to Engineering and Environmental Problems 2005 2005
DOI: 10.4133/1.2923455
|View full text |Cite
|
Sign up to set email alerts
|

ALLTEM, a Triangle Wave On‐Time Time‐Domain System for UXO Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Practically, the use of a triangle‐waveform results in smaller early‐time voltages induced in the Rx loops reducing dynamic‐range demands on the receiver analogue electronics and the digitizer. Another useful consequence is that ferrous and non‐ferrous targets generate markedly different responses (Wright et al . 2005, 2006).…”
Section: Alltemmentioning
confidence: 99%
See 2 more Smart Citations
“…Practically, the use of a triangle‐waveform results in smaller early‐time voltages induced in the Rx loops reducing dynamic‐range demands on the receiver analogue electronics and the digitizer. Another useful consequence is that ferrous and non‐ferrous targets generate markedly different responses (Wright et al . 2005, 2006).…”
Section: Alltemmentioning
confidence: 99%
“…Pre‐processing of ALLTEM data involves removing the system response and background signature from the recorded waveforms, applying lowpass and bandpass filters, merging GPS information (which is converted from latitude–longitude to UTM easting–northing) with the waveforms, averaging the bipolar waveforms (1111 samples are reduced to 555 samples), integrating the area under waveforms to produce an indicator of composition (ferrous, non‐ferrous or mixed) and exporting the data in a form suitable for input to Geosoft's Oasis Montaj program that is useful for database management and data analysis (Wright et al . 2005).…”
Section: Alltemmentioning
confidence: 99%
See 1 more Smart Citation
“…The ALLTEM induction system uses a triangle wave transmitter waveform that excites both a transient electro-dynamic response and a magneto-static response [8]. The instrument has a coil array contained on a one-meter square cube (see Figure 1).…”
Section: Alltem Modelingmentioning
confidence: 99%
“…Fully polarimetric datasets greatly reduce ambiguity in target characterization [6,7]. Examples of fullypolarimetric systems include the U.S. Geological Survey's ALLTEM system [8], the Berkeley UXO Discriminator [9], and the MetalMapper (D. Snyder and D. George, pers. comm., November 2009).…”
Section: Introductionmentioning
confidence: 99%