2021
DOI: 10.1016/j.vaa.2020.08.009
|View full text |Cite
|
Sign up to set email alerts
|

Along or across the visual axis: a comparison of two ultrasound screen, needle and transducer orientation techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

5
2

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 11 publications
0
5
0
1
Order By: Relevance
“…For the US-guided SN block technique, a 21-gauge, 50 mm echogenic insulated needle (Echoplex, Vygon, Swindon, UK) with an attached extension line primed with the injectate solution was inserted through the tensor fascia latae muscle in a cranio-caudal orientation towards the neurovascular bundle. The along visual axis technique (the long axis of ultrasound probe was along the operator’s visual axis and ultrasonic beam and vertical to the surface) and in-plane needling approach were used to perform the US-guided SN block with lidocaine-dye mixture injections in all cadavers [ 22 ]. The position of the tip of the needle was deemed satisfactory when it pierced the medial femoral fascia containing the SN and the FA and Femoral vein (FV).…”
Section: Methodsmentioning
confidence: 99%
“…For the US-guided SN block technique, a 21-gauge, 50 mm echogenic insulated needle (Echoplex, Vygon, Swindon, UK) with an attached extension line primed with the injectate solution was inserted through the tensor fascia latae muscle in a cranio-caudal orientation towards the neurovascular bundle. The along visual axis technique (the long axis of ultrasound probe was along the operator’s visual axis and ultrasonic beam and vertical to the surface) and in-plane needling approach were used to perform the US-guided SN block with lidocaine-dye mixture injections in all cadavers [ 22 ]. The position of the tip of the needle was deemed satisfactory when it pierced the medial femoral fascia containing the SN and the FA and Femoral vein (FV).…”
Section: Methodsmentioning
confidence: 99%
“…Ultrasound-guided sciatic, saphenous and obturator nerve blocks were performed as previously described [14][15][16] using 0.1 mL kg − 1 0.5% ropivacaine (Naropina; AstraZeneca, Verona, Italy). All blocks were performed using an in-plane visual axis technique 17 with a dedicated echogenic needle (Visioplex, Vygon Italia S.r.l., Padua, Italy) and a linear transducer (HFL50, 15-6 MHz Linear Transducer). Operators performing blocks and clinicians monitoring patients throughout the intra-and postoperative periods were blinded to the study CRI administered.…”
Section: Study Protocolmentioning
confidence: 99%
“…All blocks were performed by the same anesthetist (M.D.) using an along visual axis technique [28] with a dedicated veterinary ultrasound system (Sonosite S II Veterinary Ultrasound System, Fujifilm Italia S.p.a., Milan, Italy) and a linear ultrasound probe (HFL50, 15-6 MHz Linear Transducer). The QLB LQL-T was performed as described by Garbin et al [17] using an 85 mm echogenic needle for nerve blocks (Visioplex, Vygon Italia S.r.l., Padua, Italy).…”
Section: Preoperative Managementmentioning
confidence: 99%