Handbook of Radioactivity Analysis 2012
DOI: 10.1016/b978-0-12-384873-4.00006-2
|View full text |Cite
|
Sign up to set email alerts
|

Alpha Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 205 publications
0
6
0
Order By: Relevance
“…Calculation of sample activity does not require a knowledge of counting efficiency ε , while for the calculation of chemical recoveries R this value is needed. Many laboratories determine chemical recoveries because it is a suitable tool for checking the quality of performed analyses [ 8 ]. The counting efficiency depends not only on the sample—detector distance, but also the diameter of the source on which alpha emitting isotopes are deposited.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Calculation of sample activity does not require a knowledge of counting efficiency ε , while for the calculation of chemical recoveries R this value is needed. Many laboratories determine chemical recoveries because it is a suitable tool for checking the quality of performed analyses [ 8 ]. The counting efficiency depends not only on the sample—detector distance, but also the diameter of the source on which alpha emitting isotopes are deposited.…”
Section: Resultsmentioning
confidence: 99%
“…Efficiency calculations were usually performed using the Monte Carlo code MCNP [ 8 ]. In this case Monte Carlo simulation was also applied.…”
Section: Resultsmentioning
confidence: 99%
“…The sample was measured in both techniques under similar conditions discussed below. The parameters characterizing the stability of the system are the peak location, the FWHM, and the counting efficiency of a selected radionuclide present in the standard source [24].…”
Section: Quality Control For 𝛼 −Spectrometersmentioning
confidence: 99%
“…The performance of the RAD-7 instrument was verified by counting the sample from the same source in the LSC [24]. The same standard sample containing at least two 𝛼 −emitting radionuclides, which are 218 Po and 214 Po, was used to check their energies, the Full Width Half Maximum (FWHM) and the efficiency calibration of the detector or 𝛼 −spectrometer [24]. The sample was measured in both techniques under similar conditions discussed below.…”
Section: Quality Control For 𝛼 −Spectrometersmentioning
confidence: 99%
“…A number of reviews have been published at various times by researchers about source preparation, de-convolution algorithms, and applications of a-spectrometry. [9][10][11][12][13][14][15][16] However, there is no review available that deals with all these topics. The present review is written with the objective to summarize the role of AS in nuclear, environmental and biological sciences.…”
Section: Introductionmentioning
confidence: 99%