“…The following four cases are considered for the FEA: flux density alternating in the RD, alternating in the 45 • direction (ALT45), alternating in the TD, and rotating in the counter clock-wise direction (ROT). The anisotropic JA model (AJAM) utilizes the anhysteretic magnetization from alternating BH measurements in seven directions: 0 • , 15 • , 30 • , … , 90 • [30]. Moreover, the JA model's parameters vary as a function of the magnitude and polar direction of the flux density [31].…”