Aluminium leaching in fluid warming devices – A Review

Abstract: Current guidelines recommend the use of an intravenous fluid warmer to prevent perioperative hypothermia. Among the various methods of warming intravenous fluids, contact warmers are among the most effective and accurate, particularly in clinical conditions requiring rapid infusions of refrigerated blood or fluids. Contact warmers put the infusate in direct contact with a heating block. Some fluid warmers use heating blocks manufactured from aluminium. Several recent publications, however, have shown that unco… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
1
1

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…15 The newer cartridge has been extensively tested in a bench environment for the release of aluminum, other potentially toxic elements, and organic molecules with favorable results. 16 22 Additional bench testing also confirmed that the newer parylene-coated enFlow design warmed fluids as efficiently as the previous design; however, the performance of the parylene-coated enFlow has not been evaluated in a clinical setting. 16 …”
Section: Introductionmentioning
confidence: 89%
See 1 more Smart Citation
“…15 The newer cartridge has been extensively tested in a bench environment for the release of aluminum, other potentially toxic elements, and organic molecules with favorable results. 16 22 Additional bench testing also confirmed that the newer parylene-coated enFlow design warmed fluids as efficiently as the previous design; however, the performance of the parylene-coated enFlow has not been evaluated in a clinical setting. 16 …”
Section: Introductionmentioning
confidence: 89%
“…15 The newer cartridge has been extensively tested in a bench environment for the release of aluminum, other potentially toxic elements, and organic molecules with favorable results. [16][17][18][19][20][21][22] Additional bench testing also confirmed that the newer parylene-coated enFlow design warmed fluids as efficiently as the previous design; however, the performance of the parylene-coated enFlow has not been evaluated in a clinical setting. 16 To further assess this improved design in a clinical setting, this trial evaluated the efficacy of the new parylenecoated enFlow IV fluid and blood warming system in maintaining normothermia in patients undergoing surgery.…”
Section: Verification Of An Intravenous Fluid Warmer: a Prospective T...mentioning
confidence: 99%
“…[15] The newer cartridge has been extensively tested in a bench environment for the release of aluminium, other potentially toxic elements, and organic molecules with favorable results. [16][17][18][19][20][21][22] Additional bench testing also con rmed that the newer parylene-coated enFlow design warmed uids as e ciently as the previous design; however, the performance of the parylene-coated enFlow has not been evaluated in a clinical setting. [16] To further assess this improved design in a clinical setting, this study evaluated the e cacy of the new parylene-coated enFlow IV uid and blood warming system in maintaining normothermia in patients undergoing surgery.…”
Section: Introductionmentioning
confidence: 99%