Abstract:Four sorts of graphite bed in a laboratory tower reactor for amalgam decomposition were compared. Measurements were performed at 80°C, concentration of
normalNaOH
40%, rate of flow of amalgam 0.0125 mol/cm2 sec, and concentration of sodium in amalgam 0.03–0.7 weight per cent; decomposition of the amalgam was maximum with crushed graphite of the firm Sigri (West Germany).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.