2015
DOI: 10.1681/asn.2014121233
|View full text |Cite
|
Sign up to set email alerts
|

Ambient Melamine Exposure and Urinary Biomarkers of Early Renal Injury

Abstract: Information about environmental exposure to melamine and renal injury in adults is lacking. We investigated this relationship in 44 workers at two melamine tableware manufacturing factories in Taiwan (16 manufacturers, eight grinders, ten packers, and ten administrators) and 105 nonexposed workers (controls) at one shipbuilding company who were enrolled in August-December of 2012. For melamine workers, personal and area air samples were obtained at the worksite over 1 workweek (Monday-Friday). In the same week… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
32
2

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 49 publications
(35 citation statements)
references
References 30 publications
1
32
2
Order By: Relevance
“…Multiple reaction monitoring (MRM) mode was used. The characteristic fragmentation transitions m/z 127 > 85 for melamine and m/z 133 > 89 for the IS were used for quantification and m/z 127 > 68 for melamine was used for quantitative confirmation analysis with the dwell time set at 100 ms, and unit resolution (Figure ). Figures A and B show signals of ion chromatograms for placenta unfortified with the melamine standard and fortified with 100 ng/mL of melamine standard, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Multiple reaction monitoring (MRM) mode was used. The characteristic fragmentation transitions m/z 127 > 85 for melamine and m/z 133 > 89 for the IS were used for quantification and m/z 127 > 68 for melamine was used for quantitative confirmation analysis with the dwell time set at 100 ms, and unit resolution (Figure ). Figures A and B show signals of ion chromatograms for placenta unfortified with the melamine standard and fortified with 100 ng/mL of melamine standard, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Previously, we established an analytical method for measuring melamine in urine and serum samples . In the first stage of the current study, we modified our previous procedure for measuring serum melamine to measure melamine in maternal serum in the third trimester and umbilical cord serum on date of delivery to determine whether maternal melamine exposure correlated with melamine levels in their infants. In the second stage, we established an analytical method for measuring melamine in the placenta.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations