2023
DOI: 10.1016/j.envres.2022.115061
|View full text |Cite
|
Sign up to set email alerts
|

Ambient ultrafine particle (PM0.1): Sources, characteristics, measurements and exposure implications on human health

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 37 publications
(14 citation statements)
references
References 148 publications
0
14
0
Order By: Relevance
“…PM is already known to be associated with increased mortality and morbidity 28 , and its characteristics, including concentration (measured here), size distribution, and composition (not measured here), seem to determine the extent of the health impact 29 . Particles with a diameter <10 μm can go deep into human lungs or even into the bloodstream, exacerbating respiratory and cardiovascular diseases 30 , 31 .…”
Section: Discussionmentioning
confidence: 81%
“…PM is already known to be associated with increased mortality and morbidity 28 , and its characteristics, including concentration (measured here), size distribution, and composition (not measured here), seem to determine the extent of the health impact 29 . Particles with a diameter <10 μm can go deep into human lungs or even into the bloodstream, exacerbating respiratory and cardiovascular diseases 30 , 31 .…”
Section: Discussionmentioning
confidence: 81%
“…The simulated results of source-specific UFP concentrations lay the foundation for the design of UFP control measures. Third, extensive long-term residential indoor UFP concentration monitoring is currently unavailable because the measuring instruments, such as the condensation particle counter (CPC), diffusion size classifier (DiSC), scanning mobility particle sizer (SMPS), fast mobility particle sizer (FMPS), and electrical low pressure impactor (ELPI), are too expensive for widespread use. , However, low-cost sensors for measuring the mass concentrations of PM 1 and PM 2.5 have been developed, , which are also important for the UFP number concentrations. In recent years, some potentially low-cost UFP sensors have been introduced, including the micro aerosol sensor, miniature polydisperse aerosol sensor, microelectromechanical (MEMS) particle detection system, miniature electrical ultrafine particle sizer (mini-eUPS) prototype, bipolar ion source sensor, ionization sensor, integrated electrical condensation particle counter, and modified MEMS-based integrated sensor (Table S21).…”
Section: Resultsmentioning
confidence: 99%
“…PMs are classified according to their particle diameters, such as PM 10 (diameter less than 10 μm), PM 2.5 (diameter 2.5 to 10 μm), and PM 0.1 (also known as uf-UPs, diameter less than 0.1 μm), and are considered harmful factors affecting health as they can induce various pathologies, including cardiovascular toxicity, pulmonary diseases, hematological aberration, cutaneous inflammation, and metabolic syndrome [ 32 , 33 , 34 , 35 , 36 ]. Although uf-UPs are less well known than PM 2.5 and PM 10, recent studies have shown that uf-UPs pose a more serious danger to human health because they can be translocated into the bloodstream, spread to other organs, and have thus been positively associated with COPD, cardiovascular diseases, congestive heart failure, preterm birth, asthma, and acute myocardial infarction [ 37 ]. Therefore, effective prevention and treatment are required to reduce the health risks of exposure to uf-UPs.…”
Section: Discussionmentioning
confidence: 99%