2022
DOI: 10.3390/en15239171
|View full text |Cite
|
Sign up to set email alerts
|

Ammonia Removal by Simultaneous Nitrification and Denitrification in a Single Dual-Chamber Microbial Electrolysis Cell

Abstract: Ammonia removal from wastewater was successfully achieved by simultaneous nitrification and denitrification (SND) in a double-chamber microbial electrolysis cell (MEC). The MEC operations at different applied voltages (0.7 to 1.5 V) and initial ammonia concentrations (30 to 150 mg/L) were conducted in order to evaluate their effects on MEC performance in batch mode. The maximum nitrification efficiency of 96.8% was obtained in the anode at 1.5 V, followed by 94.11% at 1.0 V and 87.05% at 0.7. At 1.5 V, the ini… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 51 publications
0
2
0
Order By: Relevance
“…On their side, the remaining stock solutions were stored at 4 • C in closed plastic containers. The relatively low TMN concentration compared to the typical N concentration found in hydroponic solution (80-200 mg/L N) was chosen to limit TAN concentration, similar to what can be done in wastewater treatment plants to biologically remove N since free NH 3 can inhibit ammonia oxidizers and nitrifiers [55,62].…”
Section: Plant Materials and Growing Conditionsmentioning
confidence: 99%
“…On their side, the remaining stock solutions were stored at 4 • C in closed plastic containers. The relatively low TMN concentration compared to the typical N concentration found in hydroponic solution (80-200 mg/L N) was chosen to limit TAN concentration, similar to what can be done in wastewater treatment plants to biologically remove N since free NH 3 can inhibit ammonia oxidizers and nitrifiers [55,62].…”
Section: Plant Materials and Growing Conditionsmentioning
confidence: 99%
“…The maximum removal efficiencies of chemical oxygen demand (COD), NH 4 + -N, and total nitrogen (TN) are above 90%; meanwhile, the maximum columbic efficiency (CE) increases to 69.2%. Major studies have remarked that nitrogen removal in SCMFCs is consistent with conventional nitrification and denitrification [22,23]; however, a few researchers have thought that bioelectrochemical denitrification plays a key role in a denitrifying MFC (DNMFC) for low-COD wastewater treatment [24,25].…”
Section: Introductionmentioning
confidence: 99%