2008
DOI: 10.1016/j.bioelechem.2008.06.005
|View full text |Cite
|
Sign up to set email alerts
|

Amyloid-β detection with saccharide immobilized gold nanoparticle on carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
62
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 128 publications
(63 citation statements)
references
References 32 publications
1
62
0
Order By: Relevance
“…[19][20][21] Tamiya's group firstly proposedt he electrochemical detection of Ab monomers (Ab and Ab ) by employing ad enselyp acked sialic acid-modified electrode which can specifically capture them. [19,22] The intrinsic oxidation signal of Ab at ap eak potential of 0.6 V( vs. Ag/AgCl) was monitored by differential pulse voltammetry.T he oxidation peak current of Ab showed as imilar tendencya sA b 1-40 ,a nd the peak current intensities were concentration-dependent from 0.5 mm to 10 mm.B ased on the intrinsic oxidation signal, am ultiplexed, implantable immunosensorw as also developed for quantification of the ratio of Ab 1-40 /Ab 1-42 using triple-barrel carbon fiber microelectrodes as the sensor platform. [23] Antibodies specific to Ab and Ab as the biorecognition element of the biosensor could selectively capture the Ab isoforms on the electrode surface.…”
Section: Electrochemical Sensorsmentioning
confidence: 99%
“…[19][20][21] Tamiya's group firstly proposedt he electrochemical detection of Ab monomers (Ab and Ab ) by employing ad enselyp acked sialic acid-modified electrode which can specifically capture them. [19,22] The intrinsic oxidation signal of Ab at ap eak potential of 0.6 V( vs. Ag/AgCl) was monitored by differential pulse voltammetry.T he oxidation peak current of Ab showed as imilar tendencya sA b 1-40 ,a nd the peak current intensities were concentration-dependent from 0.5 mm to 10 mm.B ased on the intrinsic oxidation signal, am ultiplexed, implantable immunosensorw as also developed for quantification of the ratio of Ab 1-40 /Ab 1-42 using triple-barrel carbon fiber microelectrodes as the sensor platform. [23] Antibodies specific to Ab and Ab as the biorecognition element of the biosensor could selectively capture the Ab isoforms on the electrode surface.…”
Section: Electrochemical Sensorsmentioning
confidence: 99%
“…More emphasis was taken to monitor the first four hours of aggregation, and these interactions were observed through the well-documented oxidation peak of the lone Tyr residue intrinsic to Ab peptides [44,[65][66][67][68][69] at approximately 0.7 V (vs. Ag/AgCl). Electrochemical measurements done in this study were supplemented with simultaneous fluorescence measurements using the well-defined ThT as the indicator of b-sheet formation during aggregation [70][71][72].…”
Section: Ab42 and Ab16 Aggregation In The Absence Of Metal Ionsmentioning
confidence: 99%
“…Detection of the Tyr based electrooxidation signal was successfully used to monitor the in vitro aggregation of synthetic peptides representing Ab isoforms Ab and Ab(1-42) [18], as well as to study the impact of sym-triazine derivatives and the b-sheet breaker pentapeptide on Ab(1-42) aggregation kinetics [19,20]. The intrinsic oxidation signal of synthetic peptides Ab and Ab(1-42) due to the presence of the single Tyr residue was also used for the electrochemical sensing of the Ab-saccharide interaction and was suggested for the development of Ab sensor [21].…”
Section: Introductionmentioning
confidence: 99%