1994
DOI: 10.1021/ja00086a030
|View full text |Cite
|
Sign up to set email alerts
|

An ab Initio CFF93 All-Atom Force Field for Polycarbonates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
681
0
7

Year Published

1996
1996
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 1,103 publications
(692 citation statements)
references
References 0 publications
4
681
0
7
Order By: Relevance
“…Bulk structures of NTDA-ODADS/ODA (3/1) (see Figure 1) of molecular weight 4269.72 g/mol with sulfonic acid anions (-SO 3 -) anchored to the matrix, and water absorbed, were generated and simulated by means of the Accelrys commercial software (Materials Studio 3.2, Accelrys Inc., San Diego, CA) 53 using the PCFF91 force field. 54 The number of fixed ionic groups in the bulk structures was set equal to the IEC of the membrane, 1.87 mequiv/(g of dry polyelectrolyte). All the MD simulations were performed under NVT conditions with the working temperature of 298 K controlled by means of the Andersen thermostat method with a collision ratio of 1.0.…”
Section: Experimental Partmentioning
confidence: 99%
“…Bulk structures of NTDA-ODADS/ODA (3/1) (see Figure 1) of molecular weight 4269.72 g/mol with sulfonic acid anions (-SO 3 -) anchored to the matrix, and water absorbed, were generated and simulated by means of the Accelrys commercial software (Materials Studio 3.2, Accelrys Inc., San Diego, CA) 53 using the PCFF91 force field. 54 The number of fixed ionic groups in the bulk structures was set equal to the IEC of the membrane, 1.87 mequiv/(g of dry polyelectrolyte). All the MD simulations were performed under NVT conditions with the working temperature of 298 K controlled by means of the Andersen thermostat method with a collision ratio of 1.0.…”
Section: Experimental Partmentioning
confidence: 99%
“…Energy expressions for each of these nine networks were set up through the Discover Simulation Engine within Materials Studio 4.2 (henceforth referred to as MS Discover) using parameters from the PCFF [57] force-field 1 with non-bond terms being added using the Ewald summation technique [58]. Note that the PCFF forcefield was chosen in preference to the DREIDING force-field which was used in the earlier studies on the reflexynes [9] and the polytriangles [6] in view of the fact that unlike the PCFF force-field, the DREIDING force-field is unable to correctly represent the C 4v symmetry which is characteristic of single calix [4]arenes.…”
Section: Simulationsmentioning
confidence: 99%
“…In particular, only the "compass" forcefield is able to provide an adequately small dispersion of the structure factor data with our statistical samples. Thus, the older polymer consistent forcefield [20], PCFF, also based in ab initio calculations, yields more negative results 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 neighboring sites [22,23]. These parameters have been set to provide results for χ (referred to the volume of a unit) similar than those expected for our realistic samples.…”
Section: Figures 2 and 3 Contain Our S(q)mentioning
confidence: 96%