An Accurate Recognition of Infrared Retro-Reflective Markers in Surgical Navigation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…Then, the self‐developing NIOL and fiducial markers are used for spatial postural tracking, and the tracking error is less than 0.12 mm 28 . In order to improve the accuracy and real‐time performance of tracking of spatial posture of puncture needle, as shown in Figure 4, the optical tracking module is composed of two tracking tools.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Then, the self‐developing NIOL and fiducial markers are used for spatial postural tracking, and the tracking error is less than 0.12 mm 28 . In order to improve the accuracy and real‐time performance of tracking of spatial posture of puncture needle, as shown in Figure 4, the optical tracking module is composed of two tracking tools.…”
Section: Methodsmentioning
confidence: 99%
“…Then, the self-developing NIOL and fiducial markers are used for spatial postural tracking, and the tracking error is less than 0.12 mm. 28 In order to improve the accuracy and real-time performance of tracking of spatial posture of puncture needle, as shown in Figure 4, the optical tracking module is composed of two tracking tools. Tracking tool 2 completes the hand-eye calibration between the robot and NIOL to obtain the postural transformation between each coordinate system (CSM) in the whole system, and tool 1 is applied to obtain the information of needle's posture.…”
Section: Design Of the End Effector With Optical And Mechanical Feedb...mentioning
confidence: 99%
“…Traditional circular markers are used for visual measurement and medical navigation, and the angle is generally no more than 30° [19,35,36]. The marker designed in this paper can still maintain high positioning accuracy, even the angle reaches 60°.…”
Section: Positioning Experiments At Different Positionsmentioning
confidence: 95%
“…Known spatial relationships between markers and instruments can be used to determine the pose of the instrument, allowing tracking accuracies in submillimeter range. 5,6 While the tracking accuracy of EMTS can be heavily distorted by the influence of ferromagnetic material within the operation room as well as other disturbances in the generated electromagnetic field, the main challenge to tackle for OTS is the line-of-sight issue. 4 OTS are disrupted in their function as soon as the camera-setup is unable to locate the marker, which can be due caused by accidental occlusion or contamination during a surgical procedure.…”
Section: Introductionmentioning