An adaptive clinical Type 1 diabetes control protocol to optimize conventional self‐monitoring blood glucose and multiple daily‐injection therapy

Abstract: The objective of this study was to develop a safe, robust and effective protocol for the clinical control of Type 1 diabetes using conventional self-monitoring blood glucose (SMBG) measurements, and multiple daily injection (MDI) with insulin analogues.A virtual patient method is used to develop an in silico simulation tool for Type 1 diabetes using data from a Type 1 diabetes patient cohort (n = 40). The tool is used to test two prandial insulin protocols, an adaptive protocol (AC) and a conventional intensiv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 60 publications
0
3
0
Order By: Relevance
“…Note that Equations (2)- (3) define an intravenous insulin pathway, per ICU standard insulin delivery, but all pharmaco-dynamics and kinetics are otherwise general and have been used in type 1 diabetes analysis, as well [102][103][104]. The insulin kinetics in Equations (2)-(3) are similar looking to those of the well known Minimal Model, but have very different meaning as defined.…”
Section: Analysing Insulin Sensitivity In the Critically Illmentioning
confidence: 99%
“…Note that Equations (2)- (3) define an intravenous insulin pathway, per ICU standard insulin delivery, but all pharmaco-dynamics and kinetics are otherwise general and have been used in type 1 diabetes analysis, as well [102][103][104]. The insulin kinetics in Equations (2)-(3) are similar looking to those of the well known Minimal Model, but have very different meaning as defined.…”
Section: Analysing Insulin Sensitivity In the Critically Illmentioning
confidence: 99%
“…To mimic this error, 10% nor-138 mally distributed noise was applied to the BG data. Misrepresentation 139 and error are also common in a patient's carbohydrate estimates [47]. Thus, the acquired data neglected the snacks (P C ) and 10% uniformly 141 distributed noise was applied to P X .…”
Section: Data Acquisitionmentioning
confidence: 99%
“…However, this type of treatment is still exper- 46 imental and has high cost and complexity [17,4]. Hence, it may be 47 more practical to improve upon conventional approaches such as 48 self-monitored glucose with multiple daily insulin injections [46,47]. 49 Knowledge of relevant patient-specific parameters would benefit 50 model-based therapy support for insulin dosing information.…”
Section: Introductionmentioning