2015
DOI: 10.1016/j.cej.2015.01.038
|View full text |Cite
|
Sign up to set email alerts
|

An adaptive observer for operation monitoring of anaerobic digestion wastewater treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(14 citation statements)
references
References 15 publications
0
12
0
2
Order By: Relevance
“…The sum of BEPS and SMP is termed as the total EPS (TEPS). The concentration of BEPS was determined by a heat extraction method [26] with the following procedure: (1) 30-mL sludge mixture was put 14 equally into three 15-mL tubes, respectively, one of the tubes was centrifugated at 6000 rpm for 15 min with a subsequent filtration through 0.45 μm microfiber filter paper, and then the supernatant was analyzed for SMP; (2) the pellet in the tube was re-suspended into distilled water and washed for three times, then the sludge was diluted with distilled water to its original volume, and then heated to 80 0 C in a water bath for 30 min; (3) the supernatant collected after a centrifugation was regarded as EPS extraction, and the proteins were measured according to the Bradford method [27] with Bovine Serum Albumin (BSA) as standard, and the polysaccharides were determined by the phenol-sulphuric acid method [28] with glucose as standard.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The sum of BEPS and SMP is termed as the total EPS (TEPS). The concentration of BEPS was determined by a heat extraction method [26] with the following procedure: (1) 30-mL sludge mixture was put 14 equally into three 15-mL tubes, respectively, one of the tubes was centrifugated at 6000 rpm for 15 min with a subsequent filtration through 0.45 μm microfiber filter paper, and then the supernatant was analyzed for SMP; (2) the pellet in the tube was re-suspended into distilled water and washed for three times, then the sludge was diluted with distilled water to its original volume, and then heated to 80 0 C in a water bath for 30 min; (3) the supernatant collected after a centrifugation was regarded as EPS extraction, and the proteins were measured according to the Bradford method [27] with Bovine Serum Albumin (BSA) as standard, and the polysaccharides were determined by the phenol-sulphuric acid method [28] with glucose as standard.…”
Section: Methodsmentioning
confidence: 99%
“…Multi-wavelength fluorometry was once examined for the on-line monitoring of an AD process [12], and the near infrared spectroscopy in online-monitoring of feeding substrate quality in an AD was also used for the same purpose [13]. Besides, other on-line estimation approaches were verified to be reliable in providing information towards the rapid on-line monitoring of AD processes [14], which could be used as a stand-alone and promising sensor device. However, as for the purpose of on-line monitoring and controlling, the researches performed to date have mainly focused on a single physical and chemical property as an indicator, rather than on a comprehensive index.…”
Section: Introductionmentioning
confidence: 99%
“…Some interesting works have been studied and published in ref. [27], which presents a type of adaptive observer. This adaptive observer has been used for robust estimation in a particular type of nonlinear systems.…”
Section: Overviewmentioning
confidence: 99%
“…However, the dilution rate controls the convergence rate when utilizing asymptotic observes. Simultaneous estimating of model parameters and the state of the process can be performed with adaptive observers . Alternatively, using the process model and its known parameters allows the tailoring of nonlinear observers with the nonlinearity of the process accounted for by the algorithm .…”
Section: Emerging Spr Sensor Technologies For Admentioning
confidence: 99%