2021
DOI: 10.1016/j.foodchem.2020.127559
|View full text |Cite
|
Sign up to set email alerts
|

An alkaline dissolution-based method using tetramethylammonium hydroxide for metals determination in cow milk samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…Additionally, a cow skimmed powdered milk certified reference material for trace metals (Skimmed Milk powder ERM®‐BD150 from Sigma‐Aldrich) was used to assess the method's performance. For natural samples, potassium, calcium, zinc, and iron were measured by flame atomic absorption spectrometry, employing a modified procedure 30 . Likewise, total fat content was determined by the Gerber method 31 .…”
Section: Methodsmentioning
confidence: 99%
“…Additionally, a cow skimmed powdered milk certified reference material for trace metals (Skimmed Milk powder ERM®‐BD150 from Sigma‐Aldrich) was used to assess the method's performance. For natural samples, potassium, calcium, zinc, and iron were measured by flame atomic absorption spectrometry, employing a modified procedure 30 . Likewise, total fat content was determined by the Gerber method 31 .…”
Section: Methodsmentioning
confidence: 99%
“…30,35–38 As compared to the use of acids, the solubilization of sample components with TMAH is simpler and faster than that with acids, usually efficient at room temperature, minimizing the risk of volatile analyte losses, and requires only small portions of the reagent. 30,35…”
Section: Introductionmentioning
confidence: 99%
“…34 Apart from that, it is also applied for the decomposition of samples of different matrices, before their analysis with the aid of conventional large-scale instrumentation. 30,[35][36][37][38] As compared to the use of acids, the solubilization of sample components with TMAH is simpler and faster than that with acids, usually efficient at room temperature, minimizing the risk of volatile analyte losses, and requires only small portions of the reagent. 30,35 To the best of our knowledge, there is no comprehensive study focusing on the generation of FLC-APGD (and other similar systems such as ELCAD or SCGD) in contact with alkalized solutions.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation