2005
DOI: 10.1109/tec.2005.847998
|View full text |Cite
|
Sign up to set email alerts
|

An Analysis of the Control and Operation of a Solid Oxide Fuel-Cell Power Plant in an Isolated System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
96
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 148 publications
(97 citation statements)
references
References 8 publications
1
96
0
Order By: Relevance
“…It is shown that the response time of the stack terminal voltage and temperature after a step change of the dc output power is very close to what have been reported in [16]. 0-D SOFC models have been widely used for load tracking studies under both stand-alone and grid-connected conditions [21][22][23]. Such a lumped-parameter model can emulate the FC operations with acceptable accuracy only if certain strict assumptions are met, e.g., the fuel utilization factor is constant [11].…”
Section: Introductionsupporting
confidence: 66%
See 1 more Smart Citation
“…It is shown that the response time of the stack terminal voltage and temperature after a step change of the dc output power is very close to what have been reported in [16]. 0-D SOFC models have been widely used for load tracking studies under both stand-alone and grid-connected conditions [21][22][23]. Such a lumped-parameter model can emulate the FC operations with acceptable accuracy only if certain strict assumptions are met, e.g., the fuel utilization factor is constant [11].…”
Section: Introductionsupporting
confidence: 66%
“…Typically, Tmin = 1173 K, Tmax = 1273 K, Pmin = 0.1 pu and Pmax = 1 pu of the SOFC rated power [1,23].…”
Section: Operating Variables and Constraintsmentioning
confidence: 99%
“…Usually, hydrogen is as fuel gas and cheap air is as oxidant gas. Based on constant output voltage mode of SOFC, in the practical operation, the outside resistance load demand is met by the use of providing the proper amount of hydrogen and air, meanwhile, it is necessary to keep SOFC constant output voltage [20] and fuel utilization rate within a safe range. The fuel utilization rate is to be the ratio of the amount of hydrogen that generates electrochemical reaction in the SOFC to the amount of hydrogen that is fed into the SOFC, it is an important parameter influencing the performance of SOFC system.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, many dynamic models of SOFC have been reported by researchers (Padulles et al, 2000;Zhu & Tomsovic, 2002;Sedghisigarchi & Feliachi, 2004;Li et al, 2005;Goel et al, 2006;Wang & Nehrir, 2007a). Padulles et al presented a basic SOFC dynamic model which considers only ohmic voltage loss.…”
Section: Introductionmentioning
confidence: 99%
“…But, a fuel reformer was not considered in their model. Li et al, (2005) only added a methanol reformer to the model proposed in Padulles et al, (2000). They suggested two control schemes as constant utilization control and constant voltage control for the SOFC model.…”
Section: Introductionmentioning
confidence: 99%