2015
DOI: 10.1016/j.applthermaleng.2015.07.043
|View full text |Cite
|
Sign up to set email alerts
|

An analysis of the effect of the footprint orientation on the thermal-hydraulic performance of a microchannels heat sink during flow boiling of R245fa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
8
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 28 publications
(10 citation statements)
references
References 45 publications
2
8
0
Order By: Relevance
“…The experimental apparatus and the data regression procedures were validated by comparing single-phase flow data against predictions from wellestablished correlations from literature for pressure drop and heat transfer coefficient. The data considered in the validation process were obtained for R245fa as presented by Leão et al (2015). The method of Shah and London (1978) for rectangular channel and laminar flow captured reasonably well the experimental trends for the frictional pressure drop, and the method of Stephan and Preußer (1979) for laminar flow, uniform heat flux, simultaneous developing flow region and circular ducts also captured reasonably well the trends of the experimental results for heat transfer coefficient.…”
Section: Data Reductionmentioning
confidence: 66%
See 4 more Smart Citations
“…The experimental apparatus and the data regression procedures were validated by comparing single-phase flow data against predictions from wellestablished correlations from literature for pressure drop and heat transfer coefficient. The data considered in the validation process were obtained for R245fa as presented by Leão et al (2015). The method of Shah and London (1978) for rectangular channel and laminar flow captured reasonably well the experimental trends for the frictional pressure drop, and the method of Stephan and Preußer (1979) for laminar flow, uniform heat flux, simultaneous developing flow region and circular ducts also captured reasonably well the trends of the experimental results for heat transfer coefficient.…”
Section: Data Reductionmentioning
confidence: 66%
“…1, and an auxiliary circuit, used to condensate and cool down the test fluid of the refrigerant loop. Both circuits are well detailed by do Nascimento et al 2013and Leão et al (2014Leão et al ( , 2015.…”
Section: Methodsmentioning
confidence: 92%
See 3 more Smart Citations