2006
DOI: 10.1016/j.ultrasmedbio.2005.10.005
|View full text |Cite
|
Sign up to set email alerts
|

An anthropomorphic tissue-mimicking phantom of the oesophagus for endoscopic ultrasound

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
22
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(24 citation statements)
references
References 25 publications
2
22
0
Order By: Relevance
“…An increase in attenuation coefficient was expected as Al 2 O 3 has been reported to predominantly contribute to the value of attenuation coefficient (Inglis et al2006). Measured data in the 0 to 100 % particulate concentration compare favourably to those measure in a previous study by Inglis et al (2006). These data are significant as they shows that any value of attenuation coefficient within the range in soft body tissues can be obtained by choosing the appropriate scatterer concentrations.…”
Section: Discussionsupporting
confidence: 70%
“…An increase in attenuation coefficient was expected as Al 2 O 3 has been reported to predominantly contribute to the value of attenuation coefficient (Inglis et al2006). Measured data in the 0 to 100 % particulate concentration compare favourably to those measure in a previous study by Inglis et al (2006). These data are significant as they shows that any value of attenuation coefficient within the range in soft body tissues can be obtained by choosing the appropriate scatterer concentrations.…”
Section: Discussionsupporting
confidence: 70%
“…The polynomial fit was found to be of the form 0.40 f  + 0.0076 f 2 and agreed well with the earlier measurements in the frequency range of 2–7 MHz (Browne et al. 2003) and 6–15 MHz (Inglis et al. 2006) and 17–23 MHz (Brewin et al.…”
Section: Discussionmentioning
confidence: 99%
“…It has been widely used, for example in flow phantom design (Ramnarine et al. 2001), in anthropomorphic phantoms (Inglis et al. 2006) and in breast phantoms (Cannon et al.…”
Section: Introductionmentioning
confidence: 99%
“…Finally, the acoustic properties of the phantom were intermediate between water and soft tissue. The sound speed can be increased from ~1500 m/s to the expected soft tissue value of 1540 m/s by addition of a small quantity of glycerol (Inglis et al 2006). Attenuation can also be increased with BSA.…”
Section: Discussionmentioning
confidence: 99%