1983
DOI: 10.1109/irps.1983.361964
|View full text |Cite
|
Sign up to set email alerts
|

An Appraisal of High Temperature Humidity Stress Tests for Assessing Plastic Encapsulated Semiconductor Components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

1987
1987
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Corrosion has long been one of the major failure mechanisms for plastic encapsulated silicon chips (1,2). Historically, there have been two major failure mechanisms associated with VLSI corrosion: bond pad corrosion (3,4) (typically due to the influx of chlorine ions from the package exterior), and internal corrosion (5-8) (due, in the case of phosphorus-doped passivation or flow layers, to high concentrations of phosphorus). More recently, there has been a movement to increase the integrity of the passivation overcoat, while at the same time reducing the concentration of phosphorus in the layer of oxide beneath the metallization.…”
mentioning
confidence: 99%
“…Corrosion has long been one of the major failure mechanisms for plastic encapsulated silicon chips (1,2). Historically, there have been two major failure mechanisms associated with VLSI corrosion: bond pad corrosion (3,4) (typically due to the influx of chlorine ions from the package exterior), and internal corrosion (5-8) (due, in the case of phosphorus-doped passivation or flow layers, to high concentrations of phosphorus). More recently, there has been a movement to increase the integrity of the passivation overcoat, while at the same time reducing the concentration of phosphorus in the layer of oxide beneath the metallization.…”
mentioning
confidence: 99%
“…Thus, in testing bipolar plastic encapsulated devices (PEDs) from six manufacturers, Merrett et af. 16 found that the relative failure rate difference between them at high temperature was smaller than at low temperature, although the ranking remained the same. This could be expressed either by saying that nT is dependent on quality, or that no is dependent on temperature.…”
mentioning
confidence: 87%
“…In experiments in which the life of a device is to be predicted by accelerated aging at two or more elevated temperatures, batch sizes of 50 or more have been used (e.g. Merret [16]), and this apparatus can be configured for such an experiment, but it would not be suitable for the >600 samples in each batch used by, for example, Nachbauer [17].…”
Section: What the Apparatus Can Domentioning