2014
DOI: 10.7158/e13-108.2014.11.4
|View full text |Cite
|
Sign up to set email alerts
|

An approach to ultra-wideband channel calibration using a vector network analyser

Abstract: approach to ultra-wideband channel calibration using a vector network analyser," Australian Journal of Electrical and Electronics Engineering, vol. 11, (4) pp. 347-356, 2014. An approach to ultra-wideband channel calibration using a vector network analyser AbstractIn this paper, two calibration methods are investigated to determine the most suitable approach for ultrawideband (UWB) communication channel measurements. The fi rst method is the through, open, short and match (TOSM) calibration technique. The s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 36 publications
0
6
0
Order By: Relevance
“…In all measurements, TRL calibration was used to get accurate measurement results. Further details of this calibration procedure can be found in [40] For this study, the noise power of the device (VNA) has been measured at 10 kHz, 1 kHz and 10 Hz, as shown in Figure 16 where we can see that, decreasing the IF bandwidth, decreases the noise power. This leads to a corresponding increase in the time taken to measure the channel (as shown in Table 1 on sweep time).…”
Section: Measurement Methodologymentioning
confidence: 99%
“…In all measurements, TRL calibration was used to get accurate measurement results. Further details of this calibration procedure can be found in [40] For this study, the noise power of the device (VNA) has been measured at 10 kHz, 1 kHz and 10 Hz, as shown in Figure 16 where we can see that, decreasing the IF bandwidth, decreases the noise power. This leads to a corresponding increase in the time taken to measure the channel (as shown in Table 1 on sweep time).…”
Section: Measurement Methodologymentioning
confidence: 99%
“…In all measurements, TRL calibration was used to get accurate measurement results. Further details of this calibration procedure can be found in [39].…”
Section: Measurement Methodologymentioning
confidence: 99%
“…Calibrating the VNA corrects these imperfections along with other defects in measurements. Several types of calibrations can be performed depending on the application of interest [6], [13], [14]. For channel modeling, through/reciprocal calibration is performed with direct interconnection of the module's waveguide.…”
Section: B Channel Sounding Testbed Configurationmentioning
confidence: 99%