2005
DOI: 10.1016/j.ijms.2004.11.025
|View full text |Cite
|
Sign up to set email alerts
|

An assessment of the accuracy of stable Fe isotope ratio measurements on samples with organic and inorganic matrices by high-resolution multicollector ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

17
193
0

Year Published

2006
2006
2018
2018

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 210 publications
(210 citation statements)
references
References 29 publications
17
193
0
Order By: Relevance
“…Ni on 58 Fe. The correction modes for the LA data are identical to the method described and tested in detail for solution ICP-MS data by Schoenberg and von Blanckenburg (2005). The analyses were performed using the standard-sample-bracketing technique and the iron reference material IRMM-014.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Ni on 58 Fe. The correction modes for the LA data are identical to the method described and tested in detail for solution ICP-MS data by Schoenberg and von Blanckenburg (2005). The analyses were performed using the standard-sample-bracketing technique and the iron reference material IRMM-014.…”
Section: Methodsmentioning
confidence: 99%
“…The isobaric interference of 54 Cr on 54 Fe is corrected using the method described in Schoenberg and von Blanckenburg (2005) Fe ratio of samples relative to the certified IRMM-014 value, even though the instrumental mass discrimination might differ between these ratios (Albarède and Beard, 2004), 2) the 57 Fe/ 56 Fe ratio of the sample differs up to 1.5‰ from IRMM-014 and 3) the ratio 54 Cr/ 52 Cr is considered to be constant, although natural mass-dependent fractionation exists (e.g. Schoenberg et al, 2008).…”
Section: Isobaric Cr Interferencementioning
confidence: 99%
See 1 more Smart Citation
“…The calculated Fe isotope composition for bulk iron carbonate (based on estimated modal abundances of siderite and ankerite, their average Fe contents and their isotope compositions obtained by LA-ICP-MS) is -0.02‰ -this value shows no significant difference to 0.09‰ determined by solution ICP-MC and the leachates are considered representative. The Fe isotope composition of magnetite and iron carbonate were determined after chemical purification following the procedure described by Schoenberg and von Blanckenburg (2005). The obtained long-term external reproducibility of the solution ICP-MS measurements is better than ± 0.05‰ (2 SD).…”
Section: Solution Icp-msmentioning
confidence: 99%
“…27,28,34 However, using very low concentration acids could increase signals. 31 In contrast to acids' matrix effects, few studies focus on their inuences on mass bias in MC-ICP-MS. 26,35 A study on Fe isotope measurement showed that HNO 3 is superior to HCl as it yielded smaller dris of instrumental mass bias with time and better signal stability in MC-ICP-MS. 35 In addition, as outlined above, mass bias for boron isotopes is greatly affected by the type of acid and its concentration. 22,26 Given that boron is a light element and experiences relatively large mass bias (>10%) in MC-ICP-MS, 23,36 investigation of inorganic acids' effects on its behavior in the plasma may provide an isotopic perspective on mass bias and matrix effects in MC-ICP-MS.…”
Section: Introductionmentioning
confidence: 99%