2000
DOI: 10.1016/s0306-3623(01)00095-7
|View full text |Cite
|
Sign up to set email alerts
|

An association of anti-elastin IgA antibodies with development of retinopathy in diabetic children

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(29 citation statements)
references
References 18 publications
0
29
0
Order By: Relevance
“…Levels of hemoglobin A 1c and albumin excretion rate were measured as described in our previous report. 17 Neuropathy was diagnosed by clinical examination and sensory tests (skin sensation, vibration sense, light touch) supported by an electrophysiologic test (electromyography).…”
Section: Methodsmentioning
confidence: 99%
“…Levels of hemoglobin A 1c and albumin excretion rate were measured as described in our previous report. 17 Neuropathy was diagnosed by clinical examination and sensory tests (skin sensation, vibration sense, light touch) supported by an electrophysiologic test (electromyography).…”
Section: Methodsmentioning
confidence: 99%
“…In our previous study in diabetic patients, we found that the increase in AEAbs IgM and IgG suggests an initial pathological autoimmunization to human elastin while the elevation of AEAbs IgA levels -a late accelerated elastin degradation and development of vascular disease [2]. In these studies, however, it was not possible to specify which of AEAbs are components of immune complexes and which are free in the circulation.…”
Section: Discussionmentioning
confidence: 90%
“…Normally AEAbs IgG as well as IgA, IgM, IgD can be found in very low levels in the human body [14]. AEAbs from different immunoglobulin classes are present also in pathological conditions, but at much higher levels [2,[14][15][16][17][18]. α-elastin is an oxaloacetic soluble product of the insoluble "native" elastin.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…We used a method for elastin-degradation peptides (EDP) determination developed in "General Biology" Section (4,15). Every well of the used polystearene plates is flushed with antihuman monoclonal antibodies against elastin / SIGMA, USA/ (10µg/ml) with 0.05 M carbonate buffer (pH-9.6) and was incubated for three hours up to 37° C and twenty four hours at 4° C.…”
Section: Immunologic Methods For Elastin and Collagen Testingmentioning
confidence: 99%