2019
DOI: 10.1016/j.jchromb.2018.11.021
|View full text |Cite
|
Sign up to set email alerts
|

An automated system for CE-MALDI and on-target digestion under a fluorocarbon lid applied on spermatophore proteins from Pieris napi

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 40 publications
0
6
0
Order By: Relevance
“…It allows the exact determination of M r with an accuracy of ±0.1% and identification of peptides and proteins isolated by micropreparative CZE, see section 7.2. The automated system for offline CE‐MALDI‐TOF‐MS and MS/MS and on‐target tryptic digestion under fluorocarbon lid was developed using a home‐made robotic system [186]. The system was employed for analysis of spermatophore proteins of the butterfly Pieris napi .…”
Section: Detectionmentioning
confidence: 99%
“…It allows the exact determination of M r with an accuracy of ±0.1% and identification of peptides and proteins isolated by micropreparative CZE, see section 7.2. The automated system for offline CE‐MALDI‐TOF‐MS and MS/MS and on‐target tryptic digestion under fluorocarbon lid was developed using a home‐made robotic system [186]. The system was employed for analysis of spermatophore proteins of the butterfly Pieris napi .…”
Section: Detectionmentioning
confidence: 99%
“…Off-line CE-MALDI-TOF-MS and MS/MS were employed for the analysis of proteins in the spermatophore of the butterfly Pieris Napi [104]. CE separation was performed in BGE composed of 20 mM KH 2 PO 4 , pH 2.31 (adjusted with H 3 PO 4 ), and 150 μg/ml Fluorad FC-134 fluorosurfactant for dynamic capillary coating.…”
Section: Ce Coupled With Maldi-msmentioning
confidence: 99%
“…Off-line approaches have also allowed taking some advantage of advanced oxidation methods (combining H 2 O 2 and UV light) to follow the degradation of pharmaceuticals [529] or to convert alcohols into the corresponding acids, thus facilitating their separation by CE [350,530]. In order to avoid evaporation of the samples during pretreatment, Romson et al used an FC lid [531], a simple and clever approach that uses FC-770 Fluorinert (an inert, fully fluorinated liquid used in many instruments as coolant, δ = 1.79 g/mL). This off-line approach was used to incorporate trypsin digestion (2 h at room temperature) and identify sequence homologies in spermatophore proteins from Pieris napi.…”
Section: Derivatizationmentioning
confidence: 99%
“…In order to avoid evaporation of the samples during pretreatment, Romson et al. used an FC lid [531], a simple and clever approach that uses FC‐770 Fluorinert (an inert, fully fluorinated liquid used in many instruments as coolant, δ = 1.79 g/mL). This off‐line approach was used to incorporate trypsin digestion (2 h at room temperature) and identify sequence homologies in spermatophore proteins from Pieris napi .…”
Section: Direct Injection Sample Pretreatment and Preconcentrationmentioning
confidence: 99%