2017 Nineteenth International Middle East Power Systems Conference (MEPCON) 2017
DOI: 10.1109/mepcon.2017.8301192
|View full text |Cite
|
Sign up to set email alerts
|

An efficient ANFIS crowbar protection for DFIG wind turbines during faults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
24
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 13 publications
(24 citation statements)
references
References 12 publications
0
24
0
Order By: Relevance
“…The impacts of transition resistance Rg on the accuracy of the proposed technique in cases of internal and external fault are studied. It is studied in case of a three- A comparison between the proposed protection technique with others protection techniques [30][31][32] is provided as follows: Chen et al [30] have presented superconducting fault current limiter (SFCL) protection system to suppress the fault current of DFIG-Based wind farm. Wang et al [31] have proposed a flexible fault ride through strategy to allow a few wind turbine generators to trip and maintains the connection to grid of most generators during fault.…”
Section: Impacts Of Transition Resistancementioning
confidence: 99%
See 3 more Smart Citations
“…The impacts of transition resistance Rg on the accuracy of the proposed technique in cases of internal and external fault are studied. It is studied in case of a three- A comparison between the proposed protection technique with others protection techniques [30][31][32] is provided as follows: Chen et al [30] have presented superconducting fault current limiter (SFCL) protection system to suppress the fault current of DFIG-Based wind farm. Wang et al [31] have proposed a flexible fault ride through strategy to allow a few wind turbine generators to trip and maintains the connection to grid of most generators during fault.…”
Section: Impacts Of Transition Resistancementioning
confidence: 99%
“…Wang et al [31] have proposed a flexible fault ride through strategy to allow a few wind turbine generators to trip and maintains the connection to grid of most generators during fault. Noureldeen et al [32] have proposed an efficient ANFIS crowbar protection for DFIG wind turbines to protect wind turbine generator components during grid fault. The objective of the proposed technique focuses on avoiding trip events of all wind farm during faults and proposes a robust intelligent protection technique for wind farm based on ANFIS approach to trip only the faulted wind turbine.…”
Section: Impacts Of Transition Resistancementioning
confidence: 99%
See 2 more Smart Citations
“…The sudden change of stator windings voltage during faults may cause over current and over voltage in rotor windings due to magnetic coupling [5]. To avoid the damage of DFIG power electronic components, extra protection techniques must be established [6][7][8][9][10]. Currently, the grid code requires that the wind farm must remain connected to electrical grid for a specified duration time during faults, which is so-called LVRT grid code curve of wind turbines [11].…”
Section: Introductionmentioning
confidence: 99%