2016
DOI: 10.1016/j.ifacol.2016.12.064
|View full text |Cite
|
Sign up to set email alerts
|

An Efficient Control Method of Shunt Active Power Filter Using ADALINE

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 15 publications
0
9
0
Order By: Relevance
“…It is obvious that the proposal of three independent adaptive systems is needed for the three-phase design. The authors have solved the problematics in [40][41][42]46,48].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…It is obvious that the proposal of three independent adaptive systems is needed for the three-phase design. The authors have solved the problematics in [40][41][42]46,48].…”
Section: Discussionmentioning
confidence: 99%
“…Artificial intelligence techniques and soft computing techniques (adaptive neuro-fuzzy inference systems (ANFIS), adaptive linear neuron (ADALINE) ) [40][41][42][43][44][45] •…”
mentioning
confidence: 99%
“…where η is the learning rate of the ADALINE. Investigations showed that some papers studying the application of ADALINE as an extraction algorithm in SAPF such [22][23][24] use inputs generated in form of sine and cosine waves at a frequency multiple of conventional one (50 Hz or 60 Hz), taking for granted that the frequency will not fluctuate. This approach can have dramatic impacts on compensation performances in case the frequency shifts as it will be shown later in this study.…”
Section: Adaline Based Shunt Active Power Filtermentioning
confidence: 99%
“…The current values are used in (18)- (20), and conduction energy losses are calculated. The power-loss calculation process is shown in Fig.…”
Section: Power Loss Calculation Of Invertersmentioning
confidence: 99%
“…Although the auxiliary inverter acts as an active filter, the control algorithm of the inverter is easier than that of the active filters. In active filters, the reference current is calculated from the grid current using different methods [19][20][21], whereas this is more easily accomplished in the proposed system. In addition, the main purpose of utilizing the auxiliary inverter that is different from the active filter is an increased system efficiency compared to a single sixswitch three-phase inverter with an L filter.…”
mentioning
confidence: 99%