2014
DOI: 10.1016/j.jelechem.2014.09.027
|View full text |Cite
|
Sign up to set email alerts
|

An electrochemical sensor based on polyelectrolyte-functionalized graphene for detection of 4-nitrophenol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

6
31
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 60 publications
(37 citation statements)
references
References 52 publications
6
31
0
Order By: Relevance
“…21 Besides this, another talented NP chemical sensor assembled with a poly(diallyldimethylammonium chloride)-functionalized graphene composite has exhibited a dynamic result of detection limit 0.02 mM with a wider linear dynamic range from 0.06 to 110 mM. 22 Due to the high toxicity of 2-NP, sustainable development of methods for its selective detection is urgently needed. Therefore, an initiative has been taken for efficient detection of 2-NP by an electrochemical sensor constructed with Co 3 O 4 / Al 2 O 3 NSs.…”
Section: Introductionmentioning
confidence: 99%
“…21 Besides this, another talented NP chemical sensor assembled with a poly(diallyldimethylammonium chloride)-functionalized graphene composite has exhibited a dynamic result of detection limit 0.02 mM with a wider linear dynamic range from 0.06 to 110 mM. 22 Due to the high toxicity of 2-NP, sustainable development of methods for its selective detection is urgently needed. Therefore, an initiative has been taken for efficient detection of 2-NP by an electrochemical sensor constructed with Co 3 O 4 / Al 2 O 3 NSs.…”
Section: Introductionmentioning
confidence: 99%
“…Peng et al . developed an electrochemical sensor based on PDDA-functionalized graphene for the detection of 4-Nitrophenol [ 60 ]. By optimizing experimental parameters such as the pH of the buffer solution, scan rate, accumulation time and potential, the PDDA/graphene/glassy carbon electrode sensor showed remarkable sensitivity and selectivity for 4-Nitrophenol detection (concentration range of 0.06-110 µM with a detection limit of 0.02 µM S/N = 3).…”
Section: Discussionmentioning
confidence: 99%
“…S1 (see Supplementary data). For GPDDA and GPSS, in particular, a band at 270 nm appears due to the partial restoration of π-conjugation [38], characteristic of GO reduction. This reduction to form The growth of (GPDDA/GPSS) 1 /(GPDDA/GOx) 2 film was monitored by SPR, whose data are shown in Fig.…”
Section: Characterization Of Gpss and Gpddamentioning
confidence: 98%
“…The effective reduction of GO is denoted by the decrease in the interplanar distance in GPDDA and GPSS. The peak for GPDDA and GPSS is broad because it corresponds to a mixture of graphene sheets with different number of layers, which are produced as a result of different stages of functionalization of GPDDA or GPSS [38,39].…”
Section: Characterization Of Gpss and Gpddamentioning
confidence: 99%