2020
DOI: 10.1109/tpel.2019.2953162
|View full text |Cite
|
Sign up to set email alerts
|

An Enhanced Linear Active Disturbance Rejection Rotor Position Sensorless Control for Permanent Magnet Synchronous Motors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
30
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 102 publications
(30 citation statements)
references
References 22 publications
0
30
0
Order By: Relevance
“…One alternation is higher order observers. When the sinusoidal back‐EMF is taken as one state with assumption of zero derivative, a second‐order state observer or linear extended state observer (ESO) is constructed [86], [87]. Using complex vectors, the block diagram of the two equivalent linear state observers is shown in Figure 11.…”
Section: Sensorless Control Methods For Wind Generatorsmentioning
confidence: 99%
“…One alternation is higher order observers. When the sinusoidal back‐EMF is taken as one state with assumption of zero derivative, a second‐order state observer or linear extended state observer (ESO) is constructed [86], [87]. Using complex vectors, the block diagram of the two equivalent linear state observers is shown in Figure 11.…”
Section: Sensorless Control Methods For Wind Generatorsmentioning
confidence: 99%
“…The biggest advantage of the ADRC is that it can estimate the internal and external disturbances of the system and make accurate compensation. In order to obtain the control quantity and disturbance quantity information of the PMSM system, the ( 27) is further equivalently transformed [26]:…”
Section: Design Of Pmsm Speed Control System Based On Iadrcmentioning
confidence: 99%
“…The biggest advantage of the ADRC is that it can estimate the internal and external disturbances of the system and make accurate compensation. In order to obtain the control quantity and disturbance quantity information of the PMSM system, the (27) is further equivalently transformed [26]: lmatrixleftd2ωmdt2=italicbuq+αfalse(tfalse)αfalse(tfalse)=1JleftitalicdTitalicdtBdωmitalicdt3pnψf2Lsfalse(RDiq+pnψfωmfalse)+ffalse(tfalse)b=3pnψf2italicJLs…”
Section: Design Of Pmsm Speed Control Systemmentioning
confidence: 99%
“…Among them, the control strategy of the grid-side converter adopts a double closed-loop structure of voltage outer loop and current inner loop based on grid voltage vector orientation. In order to further verify the effectiveness of the method proposed in this paper, we compared the control effects of the three control methods of LADRC, E-LADRC [38] and NLADRC in the experiment. The physical parameters and controller parameters of the experimental platform are shown in Tables A1 and A2.…”
Section: Simulation Analysismentioning
confidence: 99%