2013
DOI: 10.1016/j.joen.2013.04.041
|View full text |Cite
|
Sign up to set email alerts
|

An Evaluation of Setting Time of Mineral Trioxide Aggregate and EndoSequence Root Repair Material in the Presence of Human Blood and Minimal Essential Media

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
30
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 44 publications
(32 citation statements)
references
References 11 publications
1
30
0
1
Order By: Relevance
“…To overcome this potential problem, modifications of MTA to bring about faster setting have been introduced [31]. Based on the manufacturer's instructions for use, EBC sets within 4 h and in the case of very dry canals, takes up to 10 h. During this study, it was noticed that Endosequence BC sealer and Tech sealer endo did not undergo complete setting even after 48 h. There is no available evidence on the setting time of Endosequence BC sealer, but the results are in accordance with an earlier report that presented the setting time of Endosequence root repair material [33]. This could be a reason for the poor push out BS of these materials.…”
Section: Discussionsupporting
confidence: 89%
“…To overcome this potential problem, modifications of MTA to bring about faster setting have been introduced [31]. Based on the manufacturer's instructions for use, EBC sets within 4 h and in the case of very dry canals, takes up to 10 h. During this study, it was noticed that Endosequence BC sealer and Tech sealer endo did not undergo complete setting even after 48 h. There is no available evidence on the setting time of Endosequence BC sealer, but the results are in accordance with an earlier report that presented the setting time of Endosequence root repair material [33]. This could be a reason for the poor push out BS of these materials.…”
Section: Discussionsupporting
confidence: 89%
“…Ook al wordt er geen of een lage oplosbaarheid toegeschreven aan (Charland et al, 2013;Walsh et al, 2014). Het is aangetoond dat EndoSequence ® RRM™ in een zure omgeving zal leiden tot meer poreuze en minder kristallijne microstructuren.…”
Section: Mineral Trioxide Aggregate (Mta)unclassified
“…These setting time assessment tests are based on the visual inspection of a Gillmore needle's impression into a cement surface, which is subjective. Setting time comparisons are complicated by some authors using the heavier Gillmore weight for their tests [29,53,74], which necessarily will make the setting times longer than those who use the lighter weight Gillmore needle [63]. The quantity of material tested affects the results of setting time testing, which has also made comparison of data difficult since most investigators adapt moulds for testing rather than using the precise moulds specified by the particular standard [14,49,58,64].…”
Section: Standards Used To Test Properties Of Mtamentioning