2006
DOI: 10.1007/s10694-006-8432-6
|View full text |Cite
|
Sign up to set email alerts
|

An Evaluation of Total Flooding High Expansion Foam Fire Suppression Systems for Machinery Space Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
12
0

Year Published

2006
2006
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(14 citation statements)
references
References 0 publications
2
12
0
Order By: Relevance
“…The water spray is used for reducing the smoke flow rate to the adjacent space and depleting the oxygen concentration to suppress the fire through indirect interaction, and not by direct interaction. However, if the water spray is discharged from a total flooding system, the smoke layer might disappear and the compartment would reach a well-mixed steady state with the temperature value between 50 and 70°C quickly after the water mist activation [26]. Under this condition, the compartment gas can be considered to have uniform characteristics and the time varying temperature can be employed for the whole compartment.…”
Section: Discussion On Using the Modelmentioning
confidence: 99%
“…The water spray is used for reducing the smoke flow rate to the adjacent space and depleting the oxygen concentration to suppress the fire through indirect interaction, and not by direct interaction. However, if the water spray is discharged from a total flooding system, the smoke layer might disappear and the compartment would reach a well-mixed steady state with the temperature value between 50 and 70°C quickly after the water mist activation [26]. Under this condition, the compartment gas can be considered to have uniform characteristics and the time varying temperature can be employed for the whole compartment.…”
Section: Discussion On Using the Modelmentioning
confidence: 99%
“…A large number of diffusion flames and deep-seated fires would extinguish if the ambient oxygen concentration stands below 13-15 % and 8 % respectively, as stated by Back III et al [14]. The vapor amount in saturated air at temperature above 353 K is sufficient to dilute oxygen concentration below the limit value for most fuels.…”
Section: Heat Transfer and Suppression Mecha-nismsmentioning
confidence: 94%
“…Several organizations, including The U.S. Navy [1] and The U.S. Coast Guard [2], are interested in the use of aqueous high-expansion foam (HiEx) to protect large volume, mission critical spaces such as hangar bays, well decks, vehicle stowage and magazine areas, and machinery spaces. High-expansion foam can quickly fill a room and get water to fire threats in amounts sufficient to extinguish the fires but substantially less than amounts typically delivered by deluge sprinkler water systems.…”
Section: Introductionmentioning
confidence: 99%