1987
DOI: 10.1080/09500348714551111
|View full text |Cite
|
Sign up to set email alerts
|

An Experimental Study of a Synchronously Pumped Fibre Raman Oscillator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

1989
1989
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…In some early works, researchers tended to apply nanosecond pulses as the pump, in order to reduce the difficulty of synchronization [57][58][59][60][61]. Yet, it is hard to achieve few picosecond or even femtosecond Raman pulses under such long pump pulse duration.…”
Section: Synchronously-pumped Raman Fiber Lasermentioning
confidence: 99%
“…In some early works, researchers tended to apply nanosecond pulses as the pump, in order to reduce the difficulty of synchronization [57][58][59][60][61]. Yet, it is hard to achieve few picosecond or even femtosecond Raman pulses under such long pump pulse duration.…”
Section: Synchronously-pumped Raman Fiber Lasermentioning
confidence: 99%
“…Pulse pumping is a method to improve the efficiency for the nonlinear nature of stimulated Raman scattering (SRS) . Recently, a Raman fiber laser pumped by a picosecond fiber laser demonstrated a direct out power of 0.76 W with a conversion efficiency as high as 88% and a pulse width as short as 147 fs after compression .…”
Section: Introductionmentioning
confidence: 99%
“…For efficient Raman conversion, the Stokes radiation component is amplified in a multi-pass resonant cavity with a stretch of phosphosilicate fibre between fibre Bragg grating mirrors. In pulsed operation, efficient Raman conversion is achieved with synchronous pumping [6], in which pumping pulses are synchronised with Stokes pulses of the Raman laser circulating within its cavity. Such synchronisation is established through adjusting the Raman laser cavity length so that the Raman laser round-trip time is a multiple of the pumping pulse period.…”
Section: Introductionmentioning
confidence: 99%
“…Such synchronisation is established through adjusting the Raman laser cavity length so that the Raman laser round-trip time is a multiple of the pumping pulse period. Compared to continuously pumped fibre Raman lasers, those using synchronous pulsed pumping are still much less explored [6][7][8][9], and there is exactly one published study of such a laser in an allfibre configuration with a P 2 O 5 -doped silica fibre [10] where 3-µs pulses at 1254 nm were reported. When a fibre Raman laser is pumped with broad-spectrum pulses (i.e.…”
Section: Introductionmentioning
confidence: 99%