2005
DOI: 10.3741/jkwra.2005.38.2.143
|View full text |Cite
|
Sign up to set email alerts
|

An Experimental Study on Tip Velocity and Downstream Recirculation Zone of Single Groyne Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 5 publications
1
5
0
Order By: Relevance
“…The width of recirculation field decreases as the increase of the water level and the width of board type was larger than inclined crest groyne, which was about 30% -100% as shown in Figure 9. As applying conversion permeability based on permeability of general groyne, P tr , result of the study is well agreed with previous research result by [4] as shown in Figure 10. In Figures 11 and 12, length of recirculation field decreases as water level increases and the length of board type is longer than inclined crest groyne, which is about from 45% up to 110%.…”
Section: Flow Characteristic Of Inclined Crest Groyne In Recirculatiosupporting
confidence: 81%
See 1 more Smart Citation
“…The width of recirculation field decreases as the increase of the water level and the width of board type was larger than inclined crest groyne, which was about 30% -100% as shown in Figure 9. As applying conversion permeability based on permeability of general groyne, P tr , result of the study is well agreed with previous research result by [4] as shown in Figure 10. In Figures 11 and 12, length of recirculation field decreases as water level increases and the length of board type is longer than inclined crest groyne, which is about from 45% up to 110%.…”
Section: Flow Characteristic Of Inclined Crest Groyne In Recirculatiosupporting
confidence: 81%
“…The length of recirculation zone, S L for impermeable groyne represented in 12 times of groyne length. In the case of permeable groyne, as the increase of permeability and S L was decreased [4].…”
Section: Flow Characteristic In Recirculation Zone Of Permeable and Imentioning
confidence: 99%
“…In Korea, study data related to groynes are very insufficient. Kang, et al [6] proposed an experimental formula on the recirculation zone at the downstream area through experiments on the recirculation zone at downstream groynes on the groyne line end's velocity penetration rate, approaching velocity, and groyne length as the major elements of maximum scour. Yeo, et al [7] presented the separation zone and thalweg line on the I-type, nonpenetrated groyne and carried out an experimental study on the main flow variations but did not deal with various types of groynes.…”
Section: Introductionmentioning
confidence: 99%
“…The A/D Chip maintains a 5 volt electrical pressure, and the electrical pressure changes in the standard 5 volts caused by the analog signals converts the analog signals into digital signals. It is critical for the A/D Chip to maintain an accurate and a continuous 5 volts [2]. The majority of the latest A/D Chips employ multiplexers that can handle multiple sensor inputs.…”
Section: Data Acquisition Systemmentioning
confidence: 99%
“…The signals from the sensors come in a form of a continuous analog signal, caused by the resistance in the electrical pressure [1,2]. In most cases, these signals become unreliable due to the static and the weakness of the signal as it becomes digitally converted through an elec-trical circuit in its final phase.This process is called "Signal Conditioning" [3].…”
Section: Data Acquisition Systemmentioning
confidence: 99%