An improved approach for the application of Trombe wall system to building construction with selective thermo-insulation façades

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0
1

Year Published

2010
2010
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 41 publications
(19 citation statements)
references
References 12 publications
0
18
0
1
Order By: Relevance
“…In this paper, it is to present the thermal model of themodule of the dual-function solar collector integrated with building only, and the calculation of the other components can be referred to in our former paper [14].…”
Section: Numerical Modeling Of System In Space Heating Modementioning
confidence: 99%
See 2 more Smart Citations
“…In this paper, it is to present the thermal model of themodule of the dual-function solar collector integrated with building only, and the calculation of the other components can be referred to in our former paper [14].…”
Section: Numerical Modeling Of System In Space Heating Modementioning
confidence: 99%
“…For the module of the dual-function solar collector integrated with building in space heating mode, it is necessary to analyze the heat transfer of the four main components: the glass cover, the absorber, the air heating in the air duct, and the insulation backboard. Note that the insulation backboard is treated as one added material layer of the neighbouring facade, and the calculation of insulation backboard relates to the calculation of the building facade in [14].…”
Section: Numerical Modeling Of System In Space Heating Modementioning
confidence: 99%
See 1 more Smart Citation
“…To study the performance of a novel Trombe wall with photovoltaic cells Jie et al [9]developed an unsteady numerical model, performed computations and reported results for the variation of temperature of the system over a week of time using real meteorological data. Jie et al [10] used a similar model to study the effect of selective thermo-insulation facades on the performance of a Trombe wall system and reported results of calculations for 24 hours. A similar model was developed by Shen et al [11] to compare the thermal performances of the classical Trombe wall and a composite Trombe wall in cloudy and cold climates.…”
Section: Introductionmentioning
confidence: 99%
“…Zalewski et al [10] proposed a composite Trombe wall and they tested it experimentally. Jie et al [11] proposed an improved Trombe wall to be adapted to building constructions with selective thermoinsulation façades. They affirmed that the operating efficiency of the improved Trombe wall can be up to 33.85% which represents an increase of 56%.…”
Section: Introductionmentioning
confidence: 99%