1989
DOI: 10.3181/00379727-217-rc2
|View full text |Cite
|
Sign up to set email alerts
|

An Improved Chemiluminescence Assay Suggests NGN Nitric Oxide-Mediated Action of Lysophosphatidylcholine and Acetylcholine

Abstract: A b s t r a c t . U s i n g a new n i t r i c o x i d e a n a l y s e r , we h a v e d e v e l o p e d a s e n s i t i v e c h e m i l u m i n e s c e n c e a s s a y t o d e t e c t t r a c e q u a n t i t i e s o f NO i n a q u e o u s s o l u t i o n s . T h i s improved t e c h n i q u e i n c o m b i n a t i o n w i t h t h e b i o a s s a y h a s b e e n employed t o v e r i f y t h e t h e o r y t h a t NO r e l e a s e d by v a s c u l a r e n d o t h e l i u m , a c c o u n t s f o r t h e I n t r o d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
12
0

Year Published

1991
1991
2006
2006

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(12 citation statements)
references
References 0 publications
0
12
0
Order By: Relevance
“…Quantitative measurements of NO in medium were made with a Sievers Research Redox Chemiluminescence Detector, model NOA 270 (Sievers Research, Boulder, CO). The lower limit of detection by this method is 22 pmol (22,23).…”
Section: Methodsmentioning
confidence: 99%
“…Quantitative measurements of NO in medium were made with a Sievers Research Redox Chemiluminescence Detector, model NOA 270 (Sievers Research, Boulder, CO). The lower limit of detection by this method is 22 pmol (22,23).…”
Section: Methodsmentioning
confidence: 99%
“…17 This involved injecting 10µL of deproteinised plasma samples into vanadium chloride. 18 The nitrate and nitrite present in samples were reduced to NO, and quantified from a calibration curve based on prepared concentrations of sodium nitrate.…”
Section: Laboratory Studymentioning
confidence: 99%
“…The chemiluminescence assay for NO 2 -is typically 10-fold less sensitive than the assay for NO [44,60], perhaps reflecting incomplete reduction of NO 2 -to NO. Acids other than HCl (e.g.…”
Section: + 2hmentioning
confidence: 99%
“…Most investigators report the detection threshold of the chemiluminescence assay for NO is 20-50 pmol, in liquids [6,56,57] and 1 ppb in gas. Some authors report that the chemiluminescence/NO curve is linear over the range 300-3000 pmol [60,61], while others have found a degree of nonlinearity with increasing levels of NO [43]. …”
mentioning
confidence: 99%
See 1 more Smart Citation