2019
DOI: 10.1007/s11433-019-9603-9
|View full text |Cite
|
Sign up to set email alerts
|

An improved evaluation of the neutron background in the PandaX-II experiment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
20
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 23 publications
(21 citation statements)
references
References 16 publications
1
20
0
Order By: Relevance
“…The latest observational run of PandaXII [119] had total (fiducial) mass of Xenon of 580 (330 -360) kg, approximately twice the target mass of LUX. At the energy range of 1 -10 keV ee [201] with a 54 [ton d] exposure, and background of 0.8 × 10 −3 [kg keV day] −1 [119] it essentially matched the constraining power of the most recent 2017 LUX measurements [77], as shown in Fig. 3.…”
Section: Pandaxsupporting
confidence: 67%
See 1 more Smart Citation
“…The latest observational run of PandaXII [119] had total (fiducial) mass of Xenon of 580 (330 -360) kg, approximately twice the target mass of LUX. At the energy range of 1 -10 keV ee [201] with a 54 [ton d] exposure, and background of 0.8 × 10 −3 [kg keV day] −1 [119] it essentially matched the constraining power of the most recent 2017 LUX measurements [77], as shown in Fig. 3.…”
Section: Pandaxsupporting
confidence: 67%
“…improved neutron background estimates [201] reduced this overall background to 0.66 − 0.47 × 10 −3 [kg keV day] −1 for the two separate runs that made up the full exposure PandaX is currently being upgraded to PandaX-4T, a four ton experiment with total mass of 2.8 ton in the fiducial volume [202]. In the critical range of 1-10 keV ee , the total electron recoil background 4 − 9 × 10 −5 [kg keV day] −1 and a nuclear recoil background of 2 − 8 × 10 −7 [kg keV day] −1 [202].…”
Section: Pandaxmentioning
confidence: 99%
“…The third method follows the procedure in Ref. [31], with a predicted ratio between the single-scatter NR and high energy neutron capture gammas. The residual neutron background in the dark matter data is 1.2 ± 0.6 events.…”
mentioning
confidence: 99%
“…The neutron background from detector materials is evaluated based on a new method discussed in Ref. [29], using the high energy gammas to constrain the low energy singlescattering neutrons. The total number of neutron events is estimated to be 3.0 ± 1.5 in the full exposure of PandaX-II DM search, within the final signal window and with all cuts applied.…”
Section: Backgrounds In Dark Matter Search Datamentioning
confidence: 99%