2009
DOI: 10.1016/j.chemgeo.2008.10.024
|View full text |Cite
|
Sign up to set email alerts
|

An improved method for TIMS high precision neodymium isotope analysis of very small aliquots (1–10 ng)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
111
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
4
1

Relationship

1
8

Authors

Journals

citations
Cited by 121 publications
(116 citation statements)
references
References 27 publications
4
111
1
Order By: Relevance
“…All samples (cleansed garnet separates, fine garnet powders, and rock matrices) were treated with a mixed 147 Sm-150 Nd spike prior to loading through a three-stage column chromatography procedure following Harvey and Baxter (2009). Three-column blanks with in-house, distilled 2-methyl lactic acid, run alongside all of the samples, ranged from 1-2 pg of Sm and 4-6 pg of Nd, leading to high sample-to-blank ratios, appropriate for high precision analysis at such low sample sizes.…”
Section: Methodsmentioning
confidence: 99%
“…All samples (cleansed garnet separates, fine garnet powders, and rock matrices) were treated with a mixed 147 Sm-150 Nd spike prior to loading through a three-stage column chromatography procedure following Harvey and Baxter (2009). Three-column blanks with in-house, distilled 2-methyl lactic acid, run alongside all of the samples, ranged from 1-2 pg of Sm and 4-6 pg of Nd, leading to high sample-to-blank ratios, appropriate for high precision analysis at such low sample sizes.…”
Section: Methodsmentioning
confidence: 99%
“…The issue of variable oxygen isotopic composition within the thermal ionisation source environment where isotopic fractionation could occur has been encountered in other high-precision isotopic determinations where the isotopes were measured as oxide. Notable studies include Wasserburg et al (1981) and Harvey and Baxter (2009) with TIMS NdO + measurements and associated with negative-ion TIMS Os analyses (Luguet et al, 2008). These studies documented intra-laboratory variation in R 18 , as well as within-run variation.…”
Section: Oxide Correction For Uo 2 +mentioning
confidence: 99%
“…Nd extracted from each of these leachates ranged from 2 to 7 ng. Due to their small size, the Nd was loaded with 2 μL of H 3 PO 4 and Ta 2 O 5 activator slurry onto a single Re filament and collected in static mode with amplifier rotation as NdO + (Harvey and Baxter, 2009). Procedural blanks during the timespan of these analyses were b23 pg; the effect of blank corrections was evaluated and is insignificant for this study.…”
Section: Crushleachmentioning
confidence: 99%
“…This sequential extraction resulted in five carbonate fractions from a single sample. Each leachate was dried down and brought up in 2 N nitric acid, treated with a mixed 147 Sm-150 Nd spike and passed through a three stage column procedure: an anion exchange column to remove Fe, a TRU-spec column to isolate the REEs, and a hydroxyisobutyric acid column to isolate Nd and Sm (Harvey and Baxter, 2009). …”
Section: Crushleachmentioning
confidence: 99%