2018 IEEE Energy Conversion Congress and Exposition (ECCE) 2018
DOI: 10.1109/ecce.2018.8557800
|View full text |Cite
|
Sign up to set email alerts
|

An Improved PWM Strategy for “SiC+Si” Three-Level Active Neutral Point Clamped Converter in High-Power High-Frequency Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(12 citation statements)
references
References 9 publications
0
12
0
Order By: Relevance
“…6 (a) is proposed. It uses the modulation strategy proposed in [15] where the inner switching devices (S1 -S4) are commutating at the carrier frequency and the outer switching devices (S5 -S6) are commutating at the fundamental line T frequency. In [16], the topology shown in Fig.…”
Section: Introductionmentioning
confidence: 99%
“…6 (a) is proposed. It uses the modulation strategy proposed in [15] where the inner switching devices (S1 -S4) are commutating at the carrier frequency and the outer switching devices (S5 -S6) are commutating at the fundamental line T frequency. In [16], the topology shown in Fig.…”
Section: Introductionmentioning
confidence: 99%
“…As far as the price of SiC devices is concerned, if all six switching devices in the ANPC topology are replaced with SiC devices, the high cost will limit the widespread application of such products. Considering this problem, many studies have proposed hybrid applications of SiC and silicon (Si) devices, that is, only some of the devices in a system or topology are replaced with SiC devices [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19]. In [5], a Si CSI (current source inverter)/SiC VSI (voltage source inverter) series inverter system was proposed.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, based on the diversity of ANPC topology commutation modes, various hybrid SiC and Si configuration schemes have also been proposed [8][9][10][11][12][13][14][15][16][17][18][19]. In [8][9][10][11], the outer tubes connected to the bus and clamp tubes in the ANPC topology were replaced by SiC devices. In [8][9][10][11], a medium-voltage MW-scale high-frequency SiC and Si ANPC inverter was introduced for both single-phase and three-phase pump-back tests.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…To overcome this problem, the active clamped diodes were replaced by active switches, achieving and an active neutral point clamped (ANPC) topology [9]. Although two more switches are used, it provides an additional switching state to facilitate loss distribution balancing for the whole system [10][11][12][13][14]. Among the many studies undertaken on new modulation schemes for controlling the ANPC converter, the authors of [15] proposed a new modulation scheme to perform a new commutation loop that offers better switching performance with lower stress on each switch.…”
Section: Introductionmentioning
confidence: 99%