2017
DOI: 10.1016/j.quageo.2016.11.004
|View full text |Cite
|
Sign up to set email alerts
|

An improved radiofluorescence single-aliquot regenerative dose protocol for K-feldspars

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
65
0

Year Published

2018
2018
2025
2025

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 39 publications
(68 citation statements)
references
References 38 publications
3
65
0
Order By: Relevance
“…Before determining D e values using the IRSAR IR-RF procedure, we conducted several tests to determine the most appropriate measurement conditions. Previous studies have suggested that prolonged solar bleaching (step 2 in Table S1) is required to reset the IR-RF signal (e.g., 3 hr: Frouin et al, , 2017. For our samples, however, we found that solar simulator bleaches of >1 hr did not cause a further increase in the IR-RF signalthat is, the IR-RF source traps were fully emptied by a solar simulator bleach of 1 hr (Fig.…”
Section: Multi-grain Ir-rfmentioning
confidence: 51%
See 3 more Smart Citations
“…Before determining D e values using the IRSAR IR-RF procedure, we conducted several tests to determine the most appropriate measurement conditions. Previous studies have suggested that prolonged solar bleaching (step 2 in Table S1) is required to reset the IR-RF signal (e.g., 3 hr: Frouin et al, , 2017. For our samples, however, we found that solar simulator bleaches of >1 hr did not cause a further increase in the IR-RF signalthat is, the IR-RF source traps were fully emptied by a solar simulator bleach of 1 hr (Fig.…”
Section: Multi-grain Ir-rfmentioning
confidence: 51%
“…The weighted-mean dose recovery ratios are 1.06 ± 0.03 and 1.31 ± 0.13, respectively. These results suggest that the given dose can be recovered with sufficient accuracy using the experimental conditions in our IRSAR procedure (Table S1) We also tested the RF 70 procedure (Frouin et al, 2017) on our samples. Preliminary tests showed that IR-RF measurements made at 70°C did not improve the shapes of the decay curves for our samples, in contrast to the findings of Huot et al (2015) and Frouin et al (2017).…”
Section: Multi-grain Ir-rfmentioning
confidence: 74%
See 2 more Smart Citations
“…Luminescent signals that have not yet been used for tephra dating include infrared radiofluorescence (IR-RF) (Trautmann et al, 1998(Trautmann et al, , 1999Erfurt and Krbetschek, 2003;Frouin et al, 2017) and infrared photoluminescence (IR-PL; Erfurt, 2003;Prasad et al, 2017) of K-feldspar. For these methods, the signal is recorded during ionizing irradiation (IR-RF) or during stimulation with IR radiation, respectively, but it is assumed that the sampled electron trap is the same (Kumar et al, 2018).…”
Section: Discussionmentioning
confidence: 99%